Skip to content

Fluke 116 Digital HVAC Multimeter with Temperature and Microamps

Save 11%
Original price $274.99
Current price $243.90
SKU 2538803
Currently 6 in stock.

Fluke 116 Digital HVAC Multimeter with Temperature and Microamps

Products usually ship within 1 business day.

The Fluke 116 DMM provides the features you need to quickly troubleshoot HVAC equipment

The Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.

Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.

Other useful features:

  • Measures resistance, continuity, frequency, and capacitance
  • Provides Min/Max/Average to record signal fluctuations
  • Comes with a holster with probe holders for easy storage
  • Features a compact ergonomic design for one-handed operation
  • Fits into optional ToolPak™ magnetic hanger for hands-free operation
  • CAT III 600 V safety rated

Includes:

  • 4 mm silicone test lead set
  • 80BK Integrated Temperature probe
  • Holster
  • Installed 9 V battery
  • User manual

      Fluke 116 - User's Manual

      Fluke 116 Data Sheet

       

      Specifications

      Maximum voltage between any terminal and earth ground: 600 V
      Safety: IEC 61010-1: Pollution Degree 2
      IEC 61010-2-033: CAT III 600V
      Display: Digital: 6,000 counts, updates 4 per second
      Bar Graph: 33 segments, updates 32 per second
      Operating Temperature: -10°C to +50°C
      Storage Temperature: -40°C to +60°C
      Battery Type: 9 volt Alkaline, IEC 6LR61
      Battery Life: 400 hours typical, without backlight
      DC millivolts:
      Range/Resolution
      600.0 mV / 0.1 mV
      Accuracy
      ±([% of reading] + [counts]): 0.5% + 2
      DC volts:
      Range/Resolution
      6.000 V / 0.001 V
      60.00 V / 0.01 V
      600.00 V / 0.1 V
      Accuracy
      ±([% of reading] + [counts]): 0.5% + 2
      Auto volts:
      Range/Resolution
      600.0 V / 0.1 V
      Accuracy
      2.0% + 3 (DC, 45 Hz to 500 Hz)
      4.0% + 3 (500 Hz to 1 kHz)
      AC millivolts¹ True RMS:
      Range/Resolution
      600.0 mV / 0.1 mV
      Accuracy
      1.0% + 3 (DC, 45 Hz to 500 Hz)
      2.0% + 3 (500 Hz to 1 kHz)
      AC volts¹ True RMS:
      Range/Resolution
      6.000 V / 0.001 V
      60.00 V / 0.01 V
      600.0 V / 0.1 V
      Accuracy
      1.0% + 3 (DC, 45 Hz to 500 Hz)
      2.0% + 3 (500 Hz to 1 kHz)
      Continuity:
      Range/Resolution
      600 Ω / 1 Ω
      Accuracy
      Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
      500 μs or longer.
      Ohms:
      Range/Resolution
      600.0 Ω / 0.1 Ω
      6.000 kΩ / 0.001 kΩ
      60.00 kΩ / 0.01 kΩ
      600.0 kΩ / 0.1 kΩ
      6.000 MΩ / 0.001 MΩ
      Accuracy
      0.9% + 1
      Range/Resolution
      40.00 MΩ / 0.01 MΩ
      Accuracy 5% + 2
      Diode Test: Range/Resolution
      2.00 V / 0.001 V
      Accuracy
      0.9% + 2
      Capacitance:
      Range/Resolution 1000 nF / 1 nF
      10.00 μF / 0.01 μF
      100.0 μF / 0.1 μF
      9999 μF / 1 μF
      100 μF to 1000 μF
      Accuracy 1.9% + 2
      Range/Resolution > 1000 μF
      Accuracy 5% + 20%
      Lo-Z capacitance: Range 1 nF to 500 μF
      Accuracy 10% + 2 typical
      Temperature²
      (Type-K thermocouple):
      Range/Resolution -40°C to 400°C / 0.1°C
      Accuracy 1% + 10²
      Range/Resolution -40°F to 752°F / 0.2°F
      Accuracy 1% + 18²
      AC μA true-rms (45 Hz to 500 Hz): Range/Resolution 600.0 μA / 0.1 μA
      Accuracy 1.5% + 3
      DC μamps: Range/Resolution 600.0 μA / 0.1 μA
      Accuracy 1.0% + 2
      Hz (V or A input)²: Range/Resolution 99.99 Hz / 0.01 Hz
      999.9 Hz / 0.1 Hz
      9.999 kHz / 0.001 Hz
      50.00 kHz / 0.01 Hz
      Accuracy 0.1% + 2

       

       

      1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
      2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
      3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
      2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.