Skip to content
Edmondson Supply will be closed Tuesday, December 24th & Wednesday, December 25th to celebrate Christmas. Final guaranteed shipping time is 12pm EST Monday, December 23rd. Regular shipping will resume Thursday, December 26th.
Edmondson Supply will be closed Tuesday, December 24th & Wednesday, December 25th to celebrate Christmas. Final guaranteed shipping time is 12pm EST Monday, December 23rd. Regular shipping will resume Thursday, December 26th.

Resideo DB7110U1000/U Universal Defrost Control Board - Single Stage On/Off Heat Pumps

$135.55
SKU DB7110U1000/U
Currently 3 in stock.

Resideo DB7110U1000/U Universal Defrost Control Board - Single Stage On/Off Heat Pumps

Keeps the Heat On

This multisystem defrost control for single-stage on and off heat pumps provides control of your customers' outdoor equipment—compressor contactors, reversing valves, and outdoor fans—in response to thermostat requests and air and coil temperatures. By cycling only when needed, this control helps saves energy for the homeowner.

The multisystem heat pump defrost control from Resideo helps keep the heat on during cold winter months. It is designed to be installed quickly in the tightest spaces, saving you time on the job. The defrost control works for nearly every single-stage heat pump. Keeping units of this board on hand can help ensure you'll have the right part for the job before you get there. Your customers will love this control's demand defrost algorithm that only defrosts when necessary. Other defrost controls cycle on a timer, wasting energy—ours only defrosts when needed.

  • One defrost control for nearly every single-stage heat pump reduces the need for inventory
  • Replaces more than 260 OEM and competitive models
  • Easy setup, dual LED display simplifies configuration
  • Quiet mode for defrost cycles after hours

 

Sell Sheet

Installation Instructions

 

Specifications

Application:
Single Stage Heat Pumps
Includes: Air temperature sensor with 2 pin connector; Coil temperature sensor with 3 pin connector; Wire leads; Wire nuts; Mounting screws
Comments: All terminals except FAN-IN and FAN-OUT are NEC Class 2 low voltage; FAN-IN and FAN-OUT are line voltage.
Mounting: Any Orientation, but recommended to mount so display is easily readable
Electrical Ratings: Maximum Input Current: 200 mA; Compressor Contactor: 1A @ 24 Vac; Aux Heat: 1A @ 24 Vac; Reversing Valve: 1A @ 24 Vac; Outdoor Fan: 1/2 HP motor, 5A full load, 30A locked rotor, 240 Vac.
Frequency: 60 Hz
Stages: Single Stage On/Off
Electrical Connections: 1/4 in. quick connect
Operating Humidity Range (% RH): Less than 95% RH, non-condensing
Supply Voltage: 24 Vac
Operating Temperature Range (F): -40 F to 150 F
LEDs: System LED, Fauult LED
Ambient Temperature Range (F): Coil Enable: 30 F to 36 F; Termination Temperature: 50 F to 100 F; Auxiliary Lockout Temp: 0 F to 40 F; Compressor Lockout Temp: -10 F to 40 F
Display: 4 character 7 segment display for Menu and Settings
Operation: All outputs rated for 100,000 operations

 

 

Cross Reference

Amana: C64301-1, C6431001
Arcoaire: 32312-00, 3232140
Armstrong: 39840B001, 44614-002, 47181-001, R46614-002, 39840B002, 37967B002, R44614-001, 44614-0001, 46257-001, R46257-001, R47181-001, 37967B001, R46K6701, R44614-002
Artesian: 10321-00
Carrier: 150-83-6A, CES0110063-00, CES0110063-02A, CES0130024-01, HK25SZ359A, HK32EA003, HK32EA008, HK32FA006, 621-xxxx, CES0110063-, CES0130024-, CES0130076, HK32EA001, HK32EA007, HK32FA003
Coleman 3030A374, 3C30A374, 3030A364
Comfortmaker 1029-2, 34332101, 34332100
Evcon 9218-374
Fast: 1093410
Goettl: 305007
Goodman: 1084-03-2002, 20293901, B1226008, PCBDM101, PCBDM133, PCBDM101S, 1084-200D, B1226006, LR40061, PCBDM130, PCBDM160, PCBDM130S
Heil Quaker: HQ1052727
Heil/Tempstar: 1087952, 1173636, 1087953, CEPL130524-
ICM: DFORB24A21300, DFORB-AB1004, DFOSP24A2, ICM302C, ICM304, ICM316, ICM318, ICM320, ICM322, W1001-4, ICM300C, DFORF, ICM301C, ICM303C, ICM307, ICM317, ICM319, ICM321, ICM323
ICP: 1052757
Intertherm: 6208800, 1069364
Lennox: 10026901-01, 100269-04, 11K7101, 29M0101, 30W87, 34M6301, 56M3701, 68J8401, 84W8801, 97W81, LB-101263B, 97M8101, 34M63, 56M37, 68I84, 78H68, 100269-02, 100269-05, 1507N170027, 29M0201, 33G9501, 46K67, 68I2901, 78H6801, 86G1601, LB-101263A, 11K71, 30W8701, 29M01, HPXB15, 68I29
Nordyne: 620880, 621579B, 624519A, 624626, 624644, 624700, 917178, 920338, 6246440, 6246330, 621301A, 621579A, 624608, 624633, 624656, 917012, 917178A, 624644R, 624633R
Ranco: DT2
Rheem: 47-102684-01, 47-102684-03, 47-102684-07, 47-102684-83, 47-102-685-02, 47-102685-04, 47-102685-06, 47-21517-11, 47-21517-14, 47-21517-17, 47-21517-22, 47-21517-24, 47-21776-01, 47-21776-86, DLL-013002-1RH, DDL-017002-2RH, DDL-017702-1RH, DDL-122131-2RH, 47-21517-85, 47-102684-09, 47-21517-20, 47-102684-02, 47-102684-04, 47-102684-08, 47-102685-01, 47-102685-03, 47-102685-05, 47-102685-84, 47-21517-13, 47-21517-16, 47-21517-18, 47-21517-23, 47-21517-82, 47-21517-92, 47-21776-06, DDL-013002-0RH, DDL-0131020-1RH, DDL-017102-1RH, DDL-117702-3RH, 47-21517-12, 47-102685-87, 47-102685-07
Robertshaw: DT2-1000, TD-10
SnyderGeneral: 1395-329, CEBD430524-04B
Tempstar/ICP: 1084-100, 1084-83-1008
Therm-O-Disc: 1087562
Trane: 26E-10, 21C14501G18, 21C1450127, 21C1450136, 21C1450137, 21C1450138, 21C1450142, 21C1450144, 21C1450145, 21C1450153, 21C1450154, 21C1450155, 21C1450160, 21C14282G01, CNT01106, CNT01108, CNT01129, CNT01152, CNT01431, CNT01510, CNT01642, CNT01923, CNT01924, CNT01926, CNT02514, CNT02515, CNT02516, CNT02920, CNT02935, CNT03715, CNT03716, CNT04362, CNT04363, CNT04364, CNT04366, CNT04363, CNT04695, CNT05001, CNT05008, CNT05009, CNT05010, CNT05482, CNT05875, CNT1108, CNT01693
Weatherking: 840-4-5548
White-Rodgers: 840-4-5548, 47D40-801, 47D43-101, 47D43-111, 47D43-11102, 47D43-811, 90-621, 47D01U-843
York: 031-00872-, 031-00872-002, 031-00872-701, 031-00872-703, 031-01222-, 031-01251-000, 031-01268-, 031-01954-000, 031-01975-, 031-09104-000, 031-09170-, 031-01975-001, 331-01975-, 331-09139-000, 9218-3741, S1-03100872701, S1-03109170000, S1-33101954000, S1-33101975102