Paragon 8045-20 Defrost Commercial Timer Control, 208-240V AC, 60 Hz

$119.37
SKU 8045-20
Currently 11 in stock.

Paragon 8045-20 Defrost Commercial Timer Control, 208-240V AC, 60 Hz

The Paragon® 8000 Series Commercial Defrost Controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.

 

Features and Benefits

  • Time initiated; temperature, pressure or time terminated models available
  • High-amp switch contacts: 40 Amps, 2 HP
  • Positive slider bar switch design assures positive electrical contact and wipes the contact surface of contaminates
  • Temperature or pressure terminated models are designed for defrost termination using an external temperature or pressure device
  • Safety back-up - mechanical time-driven defrost termination
  • Heavy-duty synchronous design drive motor
  • Choice of three contact arrangements
  • Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations
  • Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments
  • Heavy-duty steel enclosure with knockouts (on the bottom, back and sides) and hasp and staple padlock

 

Sell Sheet

     

    Specifications

    Series Application: 8045 Series Electric Heat, Hot Gas, or Compressor Shutdown Defrosting
    Electrical Rating: 208-240V AC, 60 Hz; 208-240V AC, 50 Hz
    Switch Rating: 120-240V AC, 690VA pilot duty, 40 Amps, 2HP (per pole)
    Enclosure: Heavy Duty Steel
    Adjustable Length of Defrost: 4-110 minutes
    Switch Arrangement for Contacts 1-3: Open
    Switch Arrangement for Contacts 2-4: Closed
    Switch Arrangements for Contacts 3-N: None
    High Pressure (Open High) Cut-Out: 3.5 (1.6)
    Agency Rating> UL Listed|UL Recognized


     

    Cross Reference

    Gemline:
    CC606, CC80452
    Grasslin: DT040ST-240, DT140ST-240
    Hussman: 4480479
    Intermatic: G8045-20
    Invensys Climate Controls: D80-8045-20
    Paragon: 3015-3, 306M, 306MB, 5X455 E355-20, 7075406, 7075406 8045-20B, 8015-3, 8045-20B, 8045-20M, 8046-20, E355-20, R3015-3, TD1071-0, TD345-3, TD546-3, TD620-3, TD684-3, TD709-3, TMR23T1, Z37844
    Quality Engin. Sys.: Q80-452
    Supco: S804520, S814120
    Uni-Line: 12405, 66201312405, 7008-002