Skip to content

ICM Controls ICM-UDEFROST Universal Defrost Control Board

Save 8%
Original price $82.65
Current price $76.07
SKU ICM-UDEFROST
Currently 20 in stock.

ICM Controls ICM-UDEFROST Universal Defrost Control Board

 

With the high cost and limited access to OEM replacement boards, the need for a singular Universal defrost control board which replaces the function of nearly all time & temperature heat pump defrost controls is a must. ICM controls has what you need with the ICM-UDefrost board. The added benefit of selecting the ICM-UDefrost is the ease of configuration using the ICM OMNI mobile App downloaded free to your Apple or Android Mobile device.

The ICM-UDefrost board monitors thermostat calls for Y, O/B and W2 inputs. During a heat call if conditions for defrost are met, the control will perform a time and temperature defrost cycle. During normal operation, the control continuously monitors safeties such as the low-pressure switch, high-pressure switch, brownout detection, and sensor health while displaying status and fault conditions via onboard LED diagnostics.

 

  • Universal time & temperature defrost board for heat pumps
  • Configurable settings with NFC
    • Compressor anti-short cycle delay
    • High ambient temperature auxiliary heat lockout
    • Low ambient temperature compressor lockout
    • Defrost end & defrost enable temperature
    • Defrost interval timer
    • Max defrost time
    • Quiet shift
    • Compressor staging delay (after brownout or at power-up)
    • Heat active/cool active reversing valve configuration
  • Field test mode
  • Brownout protection
  • LED indicators to aid in troubleshooting

 

SPECIFICATIONS:

Inputs:

  • Power Supply
    • R, C (24VAC, 50/60 Hz)
  • Thermostat
    • 24VAC, 24mA
  • Low-Pressure Switch (LPS)
    • 24VAC
  • High-Pressure Switch (HPS)
    • 24VAC
  • Outdoor Ambient Thermistor (OAT)
    • 10K ohm
  • Outdoor Coil Sensor (OCT)
    • 10K ohm
  • Field Test Button

Outputs:

  • Fan
    • N.C. ; 1/2HP, (2.7 FLA), 240 VAC
  • Compressor Contactor
    • 24VAC, 1A, Pilot Duty
  • Reversing Valve (O/B)
    • 24VAC, 1A, Pilot Duty
  • W2
    • 24VAC, 1A, Pilot Duty

Environment:

  • Operating Ambient Temperature
    • -40 C to 70 C
  • Shipping and Storage Temperature
    • -40 C to 75 C

WEIGHT/DIMENSIONS:

Length: 5.5

Width: 2

Height: 3.75

 