Resideo DB7110U1000/U Universal Defrost Control Board - Single Stage On/Off Heat Pumps
Resideo DB7110U1000/U Universal Defrost Control Board - Single Stage On/Off Heat Pumps
Keeps the Heat On
This multisystem defrost control for single-stage on and off heat pumps provides control of your customers' outdoor equipment—compressor contactors, reversing valves, and outdoor fans—in response to thermostat requests and air and coil temperatures. By cycling only when needed, this control helps saves energy for the homeowner.
The multisystem heat pump defrost control from Resideo helps keep the heat on during cold winter months. It is designed to be installed quickly in the tightest spaces, saving you time on the job. The defrost control works for nearly every single-stage heat pump. Keeping units of this board on hand can help ensure you'll have the right part for the job before you get there. Your customers will love this control's demand defrost algorithm that only defrosts when necessary. Other defrost controls cycle on a timer, wasting energy—ours only defrosts when needed.
- One defrost control for nearly every single-stage heat pump reduces the need for inventory
- Replaces more than 260 OEM and competitive models
- Easy setup, dual LED display simplifies configuration
- Quiet mode for defrost cycles after hours
Sell Sheet
Installation Instructions
Specifications
Application: |
Single Stage Heat Pumps |
Includes: |
Air temperature sensor with 2 pin connector; Coil temperature sensor with 3 pin connector; Wire leads; Wire nuts; Mounting screws |
Comments: | All terminals except FAN-IN and FAN-OUT are NEC Class 2 low voltage; FAN-IN and FAN-OUT are line voltage. |
Mounting: | Any Orientation, but recommended to mount so display is easily readable |
Electrical Ratings: | Maximum Input Current: 200 mA; Compressor Contactor: 1A @ 24 Vac; Aux Heat: 1A @ 24 Vac; Reversing Valve: 1A @ 24 Vac; Outdoor Fan: 1/2 HP motor, 5A full load, 30A locked rotor, 240 Vac. |
Frequency: | 60 Hz |
Stages: | Single Stage On/Off |
Electrical Connections: | 1/4 in. quick connect |
Operating Humidity Range (% RH): | Less than 95% RH, non-condensing |
Supply Voltage: | 24 Vac |
Operating Temperature Range (F): | -40 F to 150 F |
LEDs: | System LED, Fauult LED |
Ambient Temperature Range (F): | Coil Enable: 30 F to 36 F; Termination Temperature: 50 F to 100 F; Auxiliary Lockout Temp: 0 F to 40 F; Compressor Lockout Temp: -10 F to 40 F |
Display: | 4 character 7 segment display for Menu and Settings |
Operation: | All outputs rated for 100,000 operations |
Cross Reference
Amana: | C64301-1, C6431001 |
Arcoaire: | 32312-00, 3232140 |
Armstrong: | 39840B001, 44614-002, 47181-001, R46614-002, 39840B002, 37967B002, R44614-001, 44614-0001, 46257-001, R46257-001, R47181-001, 37967B001, R46K6701, R44614-002 |
Artesian: | 10321-00 |
Carrier: | 150-83-6A, CES0110063-00, CES0110063-02A, CES0130024-01, HK25SZ359A, HK32EA003, HK32EA008, HK32FA006, 621-xxxx, CES0110063-, CES0130024-, CES0130076, HK32EA001, HK32EA007, HK32FA003 |
Coleman | 3030A374, 3C30A374, 3030A364 |
Comfortmaker | 1029-2, 34332101, 34332100 |
Evcon | 9218-374 |
Fast: | 1093410 |
Goettl: | 305007 |
Goodman: | 1084-03-2002, 20293901, B1226008, PCBDM101, PCBDM133, PCBDM101S, 1084-200D, B1226006, LR40061, PCBDM130, PCBDM160, PCBDM130S |
Heil Quaker: | HQ1052727 |
Heil/Tempstar: | 1087952, 1173636, 1087953, CEPL130524- |
ICM: | DFORB24A21300, DFORB-AB1004, DFOSP24A2, ICM302C, ICM304, ICM316, ICM318, ICM320, ICM322, W1001-4, ICM300C, DFORF, ICM301C, ICM303C, ICM307, ICM317, ICM319, ICM321, ICM323 |
ICP: | 1052757 |
Intertherm: | 6208800, 1069364 |
Lennox: | 10026901-01, 100269-04, 11K7101, 29M0101, 30W87, 34M6301, 56M3701, 68J8401, 84W8801, 97W81, LB-101263B, 97M8101, 34M63, 56M37, 68I84, 78H68, 100269-02, 100269-05, 1507N170027, 29M0201, 33G9501, 46K67, 68I2901, 78H6801, 86G1601, LB-101263A, 11K71, 30W8701, 29M01, HPXB15, 68I29 |
Nordyne: | 620880, 621579B, 624519A, 624626, 624644, 624700, 917178, 920338, 6246440, 6246330, 621301A, 621579A, 624608, 624633, 624656, 917012, 917178A, 624644R, 624633R |
Ranco: | DT2 |
Rheem: | 47-102684-01, 47-102684-03, 47-102684-07, 47-102684-83, 47-102-685-02, 47-102685-04, 47-102685-06, 47-21517-11, 47-21517-14, 47-21517-17, 47-21517-22, 47-21517-24, 47-21776-01, 47-21776-86, DLL-013002-1RH, DDL-017002-2RH, DDL-017702-1RH, DDL-122131-2RH, 47-21517-85, 47-102684-09, 47-21517-20, 47-102684-02, 47-102684-04, 47-102684-08, 47-102685-01, 47-102685-03, 47-102685-05, 47-102685-84, 47-21517-13, 47-21517-16, 47-21517-18, 47-21517-23, 47-21517-82, 47-21517-92, 47-21776-06, DDL-013002-0RH, DDL-0131020-1RH, DDL-017102-1RH, DDL-117702-3RH, 47-21517-12, 47-102685-87, 47-102685-07 |
Robertshaw: | DT2-1000, TD-10 |
SnyderGeneral: | 1395-329, CEBD430524-04B |
Tempstar/ICP: | 1084-100, 1084-83-1008 |
Therm-O-Disc: | 1087562 |
Trane: | 26E-10, 21C14501G18, 21C1450127, 21C1450136, 21C1450137, 21C1450138, 21C1450142, 21C1450144, 21C1450145, 21C1450153, 21C1450154, 21C1450155, 21C1450160, 21C14282G01, CNT01106, CNT01108, CNT01129, CNT01152, CNT01431, CNT01510, CNT01642, CNT01923, CNT01924, CNT01926, CNT02514, CNT02515, CNT02516, CNT02920, CNT02935, CNT03715, CNT03716, CNT04362, CNT04363, CNT04364, CNT04366, CNT04363, CNT04695, CNT05001, CNT05008, CNT05009, CNT05010, CNT05482, CNT05875, CNT1108, CNT01693 |
Weatherking: | 840-4-5548 |
White-Rodgers: | 840-4-5548, 47D40-801, 47D43-101, 47D43-111, 47D43-11102, 47D43-811, 90-621, 47D01U-843 |
York: | 031-00872-, 031-00872-002, 031-00872-701, 031-00872-703, 031-01222-, 031-01251-000, 031-01268-, 031-01954-000, 031-01975-, 031-09104-000, 031-09170-, 031-01975-001, 331-01975-, 331-09139-000, 9218-3741, S1-03100872701, S1-03109170000, S1-33101954000, S1-33101975102 |