Skip to content
Edmondson Supply Will Be Closed April 29th 2024. Final guaranteed shipping time is 12pm EST Thursday, April 28th. Regular shipping will resume Monday, March 1st.
Edmondson Supply Will Be Closed April 29th 2024. Final guaranteed shipping time is 12pm EST Thursday, April 28th. Regular shipping will resume Monday, March 1st.

iO HVAC Controls ZP4-ESP-KIT 4 -Zone, Two-Position Forced Air Zone Control Panel

Save 7%
Original price $595.46
Current price $552.93
SKU ZP4-ESP-KIT
Currently 2 in stock.

iO HVAC Controls ZP4-ESP-KIT 4 -Zone, Two-Position Forced Air Zone Control Panel

The ZP4 with ESP is a 4 zone, two-position forced air zone control panel. The panel can be used with single-stage, multi-stage, heat pump or dual fuel equipment with up to 3 stages of heating and 2 stages of cooling. Slide switch configuration makes setup quick and easy. This zone control system comes with built in ESP static pressure control which eliminates the need for a bypass damper when used with the standard 3-wire MD damper series. A wide range of control options provides ultimate application flexibility.

Features

  • 4 zone universal panel with ESP capability
  • Smallest universal panel offered by iO
  • Up to 2H/2C conventional or 3H/2C heat pump and dual fuel
  • Auto changeover
  • First call priority with time share
  • 2 zone, 2nd stage capacity control
  • Purge cycle option
  • Adjustable high and low limits
  • Adjustable high and low balance points
  • Easy switch configuration
  • Fused protected inputs and outputs

Kit Includes: 

  • Panel 
  • Static pressure sensor
  • 1 duct temperature sensor
  • 40VA transformer

     

    Specifications

    Construction Aluminum enclosure with snap-on panel cover
    Mounting Snap Track with 2 back plate screws
    Dimensions 8.75” Height x 7” Width x 1.5” Depth
    Operating Temperature -40° F to 150° F
     Time Delays

    5 minute changeover

    3 minute off on high or low limit

    20 minute time share

    Discharge Air Limits

    Low Limit (30° F to 55° F)

    High Limit (100° F to 180° F)


     

    Product Brochure

    Installation Manual