Copeland White-Rodgers 50M58-956 Integrated Furnace Control, York Direct OEM Replacement
Save 56%
Original price
$482.69
Current price
$211.18
SKU 50M58-956
Copeland White-Rodgers 50M58-956 2-Stage Integrated Furnace Control for ECMx Blower Motors, York Direct OEM Replacement
Simple drop-in replacement for 120V York applications.
Direct drop-in replacement
- Direct replacement for 120V original OEM control
- Mounting matches original OEM model
Advanced diagnostics
- Simple push-button fault recall
- Tri-color LED displays status and fault codes for easy troubleshooting
Features:
- Direct replacement for 120V original OEM control
- Mounting matches original OEM model
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120V air cleaner output and 120V humidifier output up to 1 Amp max
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Specifications:
Electrical Ratings (@ 77°F [25°C])
- Input voltage: 120 VAC, 60 Hz (Class II transformer required)
- Max. input current: @ 24 VAC: 800mA + MV
- Relay load ratings: 6.0 Amp @ 120V
- 1st stage gas valve relay: 1.5amps @ 24 VAC, 60Hz
- 2nd stage gas valve relay: 0.5 amps @ 24 VAC, 60Hz
- Ignitor: 2.0 amps @ 132 VAC, 60Hz
- Inducer relays: 2.2 FLA - 3.5 LRA @ 120 VAC
- Humidifier load: 1.0 A max @ 120 VAC
- Electronic air cleaner load: 1.0 A max @ 120 VAC
- Circulator output: 12 mA RMS @ 30 VAC
Flame Current Requirements
- Min. Current to ensure flame detection: 0.3 ua DC
- Operating temp range: -40° to 175°F (-40° to 80°C)
- Humidity range: 5% to 93% relative hum. (non-condensing)
- Flame response time: 2.0 sec (max)
- Gases approved: Natural, manufactured, mixed, liquid petroleum, and LP gas air mixtures
- Board dimensions: 8.875” x 4.875”
- Agency approvals: UL
Timing Specifications (All times are in seconds, unless noted otherwise)
- Pre-purge time: 15
- Igniter warm-up time: 17
- Trial for ignition period (TFI): 4
- Ignition activation period (IAP): 3
- Retries: 2 times
- Valve sequence period: 12
- Inter-purge: 30
- Post-purge time: 15
- Lock-out time: 300
- Heat delay-to-fan-on: 30
- Heat delay-to-fan-off*: 90/120/150/180
- Cool delay-to-fan-on: 0
- Cool delay-to-fan-off: 60
- Automatic reset time: 60 mins
Kit Includes:
(1) 50M58-956 Integrated Furnace Control
(1) Installation Instructions
Cross References:
York: 031-03494-000, S1-03103494000, S1-33103494000
White-Rodgers: 50M58-242-01, 50M58-242-01B1