Skip to content
Edmondson Supply will be closed Tuesday, December 24th & Wednesday, December 25th to celebrate Christmas. Final guaranteed shipping time is 12pm EST Monday, December 23rd. Regular shipping will resume Thursday, December 26th.
Edmondson Supply will be closed Tuesday, December 24th & Wednesday, December 25th to celebrate Christmas. Final guaranteed shipping time is 12pm EST Monday, December 23rd. Regular shipping will resume Thursday, December 26th.

Resideo L8148E1265/U High Limit Vertical Mount Aquastat®, 180-240°F Range, 15°F Fixed Differential

$342.20
SKU L8148E1265/U
Currently 3 in stock.

Resideo L8148E1265/U High Limit Vertical Mount Aquastat®, 180-240°F Range, 15°F Fixed Differential

The L8148 Aquastat® Relays are immersion type hydronic controllers that combine high limit protection with switching relay control of burner and circulator motors.


FEATURES

  • High limit opens burner circuit only.
  • Requires a 24 Vac thermostat with heat anticipator set at 0.2A.

 

Sell Sheet

The Universal Choice - Selector Guide/Cross Reference for Residential Combustion Products

Installation Instructions

Product Data Sheet

 

Specifications

Application: Line Voltage Circulator Control and Low Voltage Power Supply and Limit Control, May be used with Series 60 Low Limit Control
Compatible With: Hot Water, Hydronic Heating Systems
Dimensions: 6 1/8 in. high x 4 5/16 in. wide x 3 1/8 in. deep
Maximum Safe Operating Pressure (psi): Immersion Well: 255 psi
Temperature Range (F): Maximum--150 F with 1.2 A 24 V load; 77 F with 1.4 A 24 V load
Includes: Molex® plug for use with vent damper, includes heat-conductive compound.; Molex(r) plug for use with vent damper, includes heat-conductive compound.
Mounting: Vertical Mount
Electrical Ratings: Low Voltage: 0.8 A max. @ 24 Vac; 0.25 A @ 0.25 to 12 Vdc; At Locked Rotor-- 44.4A @ 120 Vac: 22.2A @ 240 Vac
Approvals and Standards: UL Listed: File No. MP466, Vol. 13, Sec. 2, Guide No. MBPR2.
Electrical Connections: Quick-Connect / Screw
Operating Humidity Range (% RH): 0 to 95% RH, non-condensing
Voltage: 120 Vac
Bulb Size: 3/8 in. x 2 7/8 in. copper
Operating Temperature Range (F): High Limit-- 180 F to 240 F
Differential Temperature: 15 F fixed
Switching Action: SPST: High Limit & Circulator
Anticipator Setting: 0.2 A
Capillary Length: 4-1/2 in.
Insulation Depth: 1.5 in to 3 in, 38 mm to 76 mm
Electrical Ratings, Burner: At Full Load-- Low Voltage: 0.8 A max. @ 24 Vac: Line Voltage: 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- Line Voltage: 44.4 A @ 120 Vac: 22.7 A @ 240 Vac
Electrical Ratings, Circulator: At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac