{"product_id":"nu-calgon-4910-10-lx15-24vac-scorpion-uvc-led-system","title":"Nu-Calgon 4910-10 LX15 24 VAC Scorpion UVC-LED System","description":"\u003ch1\u003eNu-Calgon 4910-10 LX15 24 VAC Scorpion UVC-LED System\u003c\/h1\u003e\n\u003cdiv class=\"product-image-and-description\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-lg-6\"\u003e\n\u003cdiv class=\"nc-product-description\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e15˝ UVC-LED Disinfection System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUp to 5X the life compared to standard bulbs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRugged design with shatterproof LED\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKills mold, mildew, viruses, and bacteria on and around your HVAC coil\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStops foul odors like dirty sock smell\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated toggle switch for dual run mode options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e360 degree design for complete treatment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir flow sensor to power only when fan is running\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEasy install with integrated magnet or supplied hardware\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLX15 - Easy 24VAC input voltage on installation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptimum 265nm wavelength\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeet’s UL 2998 zero ozone emission certification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Scorpion is a UVC-LED disinfection unique system designed for use in residential and light commercial HVAC systems. The LED light has 30,000 hours of run time and with an integrated air flow sensor the Scorpion UVC-LED can last up to 5 times longer than traditional UV bulbs. The Scorpion UVC-LED is designed to kill mold, mildew, bacteria, viruses, and other harmful biological growth in the HVAC system and on the evaporator coil. The system will also help reduce foul and musty odors like dirty sock smell and will even help keep the drain line from clogging due to buildup in the condensate line.\u003cbr\u003e\u003cbr\u003eThe Scorpion is designed to treat any residential ducted HVAC system with no maintenance for up to 30,000 hours of treatment life. The system can easily be installed using the integrated magnet inside, above, or below the evaporator coil. If the Scorpion is being installed in a system where the magnet cannot be used than use the supplied hardware to mount the Scorpion to your system. The powerful LED light should be installed in a location where it is fully shining on the evaporator coil to provide complete treatment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMOUNTING DIRECTIONS:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPTION 1\u003c\/strong\u003e: Scorpion installed inside the coil using the integrated magnet\u003cbr\u003eSTEP 1: Confirm power is off to the system. Remove the access panel to the air handler.\u003cbr\u003eSTEP 2: Remove the “A” panel on the evaporator coil to gain access to the center of the coil.\u003cbr\u003eSTEP 3: Using the Scorpion’s integrated magnet, attach the Scorpion to the metal “A” panel on the far side of the evaporator coil.\u003cbr\u003eFor a “W” or “N” shaped coil, install a second Scorpion inside the second section of coil. See example image in Figure 1.4 on the full instruction bulletin.\u003cbr\u003eSTEP 4: Run the wires down the cabinet, cut a small access hole for the wires if one does not exist.\u003cbr\u003eSTEP 5: Replace the “A” panel on the evaporator coil that was previously removed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOPTION 2\u003c\/strong\u003e: Scorpion installed inside the coil using the provided hardware\u003cbr\u003eSTEP 1: Confirm power is off to the system. Remove the access panel to the air handler.\u003cbr\u003eSTEP 2: Drill a 1 ¼”  hole in the “A” plate of the evaporator.\u003cbr\u003eSTEP 3: Insert the supplied grommet into the hole drilled into the “A” plate.\u003cbr\u003eSTEP 3: Insert the LED bulb in the grommet which is placed inside of the drilled 1 ¼” opening.\u003cbr\u003eSTEP 4: Secure the Scorpion to the “A” plate using the provided hardware.\u003cbr\u003eFor a “W” or “N” shaped coil, install a second Scorpion inside the second section of coil after drilling the 1 ¼” hole in the second panel, inserting the grommet, and securing the Scorpion. See example image in Figure 1.4 on the full instruction bulletin.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOPTION 3:\u003c\/strong\u003e Scorpion installed above the coil\u003cbr\u003eSTEP 1: Confirm power is off to the system. Remove the access panel to the air handler.\u003cbr\u003eSTEP 2: Using either the integrated magnet or supplied hardware, secure the Scorpion to the side wall of the unit above the coil.\u003cbr\u003eSee figure 1.2 for example on the full instruction bulletin.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWIRING DIRECTIONS\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eFOR THE SCORPION LX15 4910-10: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSTEP 1: Connect the Scorpion to 24VAC power using the white (neutral) and black (hot) wires. The Scorpion can be wired directly to the HVAC\u003cbr\u003esystems 24VAC transformer, or add a 24VAC transformer as needed.  The Scorpion LX15 can be wired to 18-32VAC input and connected to the\u003cbr\u003edoor interlock switch so the Scorpion powers down if the door\/access panel is open. See figure 1.5 on the full instruction bulletin for wiring diagram. Wire the Scorpion to\u003cbr\u003econtinuous power, do not connect to the blower relay. See Step 2 for option modes to cycle the Scorpion with the fan.\u003cbr\u003eSTEP 2: Set the Scorpion power switch to “ON” for constant run mode. Set the power switch to “CYCLE” to run only when the fan is running and The integrated air flow sensor activates the Scorpion to power on.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(The cycle mode is recommended for longer service life for most applications.) \u003c\/strong\u003e\u003cem\u003eWhen first turning on the Scorpion in CYCLE model (air flow sensor mode) the LEDs will stay illuminated up to 120 seconds for an initial calibration. After the calibration period, the Scorpion LEDs will turn off and will then only turn back on when the fan is running and there is continuous airflow.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eSTEP 3: Replace the access panel to the unit.\u003cbr\u003eSTEP 4: Place the provided WARNING\/INSTALL DATE sticker on the exterior of the unit.\u003cbr\u003eSTEP 5: Add the date of installation using permanent marker on the sticker.\u003cbr\u003eSTEP 6: Restore power to the unit.\u003cbr\u003eSTEP 7: Register the Scorpion’s warranty at\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.nucalgon.com\/scorpion-registration\/\"\u003enucalgon.com\/scorpion-registration\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPORTANT!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 0.875rem;\"\u003eSystems with high 24 VAC loads may require the installation \u003c\/strong\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eof a separate 24 VAC transformer to power the UV light.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 0.875rem;\"\u003eAlways use a separate 24 VAC transformer with \u003c\/strong\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e“communicating” air systems.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 0.875rem;\"\u003eSome materials inside the air system (including filter media, \u003c\/strong\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eflex duct, wiring etc.) may not be UV light resistant.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eUse reflective tape to cover these components.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.nucalgon.com\/media\/8704\/3-164_scorpionlx15instr.pdf\"\u003e\u003cspan\u003e\u003cstrong\u003e4910-10 Instruction Bulletin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.nucalgon.com\/media\/8702\/3-162_scorpionlx15.pdf\"\u003e4910-10 Product Bulletin\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.nucalgon.com\/media\/8029\/4-100_iwaveapplctn.pdf\"\u003e4900-40 Application Bulletin\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/MjjQ2QveuWc?si=ASdKCFGInPVIMKxS\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":50547676119256,"sku":"4910-10","price":244.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/Screenshot2025-06-22140858.png?v=1750616414","url":"https:\/\/edmondsonsupply.com\/products\/nu-calgon-4910-10-lx15-24vac-scorpion-uvc-led-system","provider":"Edmondson Supply","version":"1.0","type":"link"}