{"product_id":"icm-controls-icm2910-205-015-fenwal-oem-replacement-dsi-control-35-725205-015","title":"ICM Controls ICM2910-205-015 Fenwal OEM Replacement DSI Control, 35-725205-015","description":"\u003ch1\u003eICM Controls ICM2910-205-015 Fenwal OEM Replacement DSI Control, 35-725205-015\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eDirect Spark Ignition (DSI) control modules\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe ICM2910 consists of a series of 11 Fenwal OEM Replacement DSI Controls. When the thermostat initiates a “Call for Heat”, the ICM2910 will perform a hardware check. After the hardware check, the ICM2910 will start a pre-purge where applicable.\u003c\/p\u003e\n\u003cp\u003eOnce the pre-purge has ended, the spark source and the gas valve relay are energized simultaneously for the duration of the trial for ignition period. A flame rectification circuit confirms the presence of the flame. Upon flame detection, the spark source is turned off.\u003c\/p\u003e\n\u003cp\u003eIf flame is not sensed, the control will turn off the spark source and gas valve and start an inter-purge where applicable before the next trial for ignition. If flame is not detected after the trial(s) for ignition, the control will enter a hard lockout. To clear the hard lockout, remove the input voltage to the control or recycle the thermostat’s heat call.\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cul\u003e\n\u003cli\u003eDirect Spark Ignition (DSI) control modules\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-based\u003c\/li\u003e\n\u003cli\u003eControls spark ignitor and gas valve\u003c\/li\u003e\n\u003cli\u003eMonitors timing, trial for ignition, flame sensing and lockout\u003c\/li\u003e\n\u003cli\u003eCompatible with LP or natural gas\u003c\/li\u003e\n\u003cli\u003eRedundant Gas valve design conforms to ANSI Z21.20\u003c\/li\u003e\n\u003cli\u003eConforms to UL STDs 60730-1 and 60730-2-5.\u003c\/li\u003e\n\u003cli\u003eCertified to CSA STD E60730-1 and CSA STD C22.2#60730-2-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\n\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2020\/12\/ss_LIS232.pdf\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e102-138 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1uA minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.5A@120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame Failure Response Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.8 seconds maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40˚F to 175˚F (-40˚C to 80˚C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.23”L x 2.53”W x 1.86”H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSurface mount using (2) #8 screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cspan\u003e **Picture is for representation only and may vary slightly**\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/03\/ICM2910-Series-Sell-Sheet.pdf\"\u003e\u003cstrong\u003eSell Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/03\/LIAF272-8-13-21.pdf\"\u003e\u003cstrong\u003eInstallation Manual \u003c\/strong\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":44144481501400,"sku":"ICM2910-205-015","price":84.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/ICM2910-series-web.png?v=1750727891","url":"https:\/\/edmondsonsupply.com\/products\/icm-controls-icm2910-205-015-fenwal-oem-replacement-dsi-control-35-725205-015","provider":"Edmondson Supply","version":"1.0","type":"link"}