{"product_id":"icm-controls-icm256c-fan-blower-control-board-replacement-for-goodman-pcbfm-103","title":"ICM Controls ICM256C Fan Blower Control Board - Replacement for Goodman PCBFM-103","description":"\u003ch1\u003eICM Controls ICM256C Fan Blower Control Board - Replacement for Goodman PCBFM-103\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eLow cost open board design\u003c\/li\u003e\n\u003cli\u003eHigh power, relay output\u003c\/li\u003e\n\u003cli\u003eDual function fan delay timer\u003c\/li\u003e\n\u003cli\u003eControls the circulating fan in heat pump, A\/C and forced air systems\u003c\/li\u003e\n\u003cli\u003eOFF delay purges ducts of residual air\u003c\/li\u003e\n\u003cli\u003eON delay allows air to reach the proper comfort level prior to energizing the fan\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eInput:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e18-30 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eOutput:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eN.O.:  25 amps @ 240 VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eFixed Time Delays:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eON:  7 seconds\u003c\/li\u003e\n\u003cli\u003eOFF:  65 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREPLACES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGoodman PCBFM-103\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMode of Operation\u003c\/strong\u003e\u003c\/p\u003e\nPower must be applied before and during the time delay period. When the initiate contact closes, the load energizes and remains energized as long as the initiate contact is closed. The time delay begins when the initiate contact opens. At the end of the time delay period, the load is turned off. If the initiate contact recloses during the time delay period the load remains energized and the time delay is reset to zero. Removal of the input power during the delay turns off the load and resets the time delay to zero. A one second interrogation delay is provided to avoid nuisance trips due to thermostat bounce or tampering.\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":52771636904152,"sku":"ICM256C","price":35.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/53YK28-A3040-1_v2.jpg?v=1792683418","url":"https:\/\/edmondsonsupply.com\/products\/icm-controls-icm256c-fan-blower-control-board-replacement-for-goodman-pcbfm-103","provider":"Edmondson Supply","version":"1.0","type":"link"}