{"product_id":"des-champs-rlc-051-3-4-hvac-waterless-trap-white-schedule-40-residential-lite-commercial-positive-negative-pressur","title":"Des Champs RLC-051 3\/4\" HVAC Waterless Trap, White Schedule 40","description":"\u003ch1\u003eDes Champs RLC-051 3\/4\" HVAC Waterless Trap, White Schedule 40 \u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"para53\"\u003e\u003cspan class=\"Style24\"\u003eDes Champs Technologies LLC has recently introduced the versatile RLC Series HVAC Air-Trap. The HVAC Air-Trap uses the air pressure generated by the fan, or gravity, to prevent air leakage from or to the air handler. The RLC Series can accommodate PVC drain pipe sizes from ½\" to 2\" and up to 40 tons of refrigeration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"para53\"\u003e\u003cspan class=\"Style24\"\u003eWhen oriented in the horizontal position it can accommodate essentially any HVAC unit negative plenum pressure and requires less than half the installation height of a standard P-trap. The lower height allows ease of installation and in many cases, reduces curb height requirements or in some cases eliminates the need for a curb. In addition, the RLC Series eliminates the following issues associated with the P-trap:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eNever requires priming or filling with water.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eSince it operates dry when there is no condensate being produced, the trap and the drain line leading to the trap will not freeze.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eThere will be no geyser effect within the HVAC unit at the beginning of cooling season as is common with a dry P-trap.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eBecause the trap operates dry when no condensate is ﬂowing there will be no accumulation of sludge. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eThe HVAC Air-Trap is predesigned so errors caused by ﬁeld designed P-traps are eliminated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eWhen the unit fan is blowing through the cooling coil the drain pan is under positive pressure. Under these conditions the RLC Series is oriented in the vertical position. In the positive pressure mode the maximum pressure in the unit plenum is 3 inches WC. All of the beneﬁts listed above are present when operating in the positive pressure mode plus the blow through that occurs on a dry P-trap is eliminated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eNegative Pressure- Orientation is Horizontal: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eCondensate flow up to 2 GPM at any negative pressure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eSchedule 40 PVC with clean out port\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRetains no water after condensing has ceased\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e3\/4\" slip internal or 1\" fitting external connection - with bushings can connect to ½, 1 ¼,  1 ½ and 2” tubes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eMeets general building codes. For use on HVAC equipment only.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePositive Pressure - Orientation is Vertical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eUp to 3\" positive pressure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eRUp to 0.5 GPM water flow (≈ 40 tons)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"para5\"\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"para5\"\u003e\u003cspan class=\"Style24\"\u003eMaximum negative pressure of WC:  20\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"para5\"\u003eMaximum positive pressure of WC:  3\"\u003c\/li\u003e\n\u003cli class=\"para5\"\u003eLength:  4.65\"\u003c\/li\u003e\n\u003cli class=\"para5\"\u003eFlammability rating: UL94 V-0\u003c\/li\u003e\n\u003cli class=\"para5\"\u003eAir-Traps Meet \u003cspan class=\"Style163\" style=\"font-size: 0.875rem;\"\u003eIMC\u003c\/span\u003e\u003cspan class=\"Style36\" style=\"font-size: 0.875rem;\"\u003e®\u003c\/span\u003e\u003cspan class=\"Style127\" style=\"font-size: 0.875rem;\"\u003e Code Section M307.2.4.1\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"para5\"\u003e\n\u003cp class=\"para5\"\u003e\u003cspan class=\"Style24\"\u003eMaximum Condensate Flow, GPM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"para5\"\u003e\n\u003cp class=\"para5\"\u003e\u003cspan class=\"Style24\"\u003eAny Negative Pressure: 2.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"para5\"\u003e\n\u003cp class=\"para5\"\u003e\u003cspan class=\"Style24\"\u003ePositive Pressure:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"para5\"\u003e\u003cspan class=\"Style24\"\u003e      0.06 at 5\" WC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"para5\"\u003e\u003cspan class=\"Style24\"\u003e      0.19 at 4\" WC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"para5\"\u003e\u003cspan class=\"Style24\"\u003e      0.21 at 3\" WC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"para5\"\u003e\u003cspan class=\"Style24\"\u003e      0.21 at 2\" WC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"para5\"\u003e \u003c\/p\u003e\n\u003cp class=\"para5\"\u003e\u003ca href=\"https:\/\/deschampstechnologies.com\/products\/rlc-series__air-trap.html\"\u003eItem Spec Sheet \u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"para5\"\u003e\u003ca href=\"https:\/\/deschampstechnologies.com\/products\/ewExternalFiles\/PMG-1697%20Final%20Report.pdf\" rel=\"noopener\" target=\"_blank\"\u003eICC-ES Report\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"para5\"\u003e \u003c\/p\u003e\n\u003cp class=\"para5\"\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/2M_2SsKdyf4?si=jxn_Ieqq1zggmvlA\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":52839740539096,"sku":"RLC-051","price":40.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/RLC051.png?v=1793310949","url":"https:\/\/edmondsonsupply.com\/products\/des-champs-rlc-051-3-4-hvac-waterless-trap-white-schedule-40-residential-lite-commercial-positive-negative-pressur","provider":"Edmondson Supply","version":"1.0","type":"link"}