{"title":"Surge Protection","description":"","products":[{"product_id":"5-2-1-tpspd-thermally-protected-surge-protection-device","title":"CPS 5-2-1 TPSPD Thermally Protected Surge Protection Device","description":"\u003ch1\u003eCPS 5-2-1 TPSPD Thermally Protected Surge Protector, 100,000 Amp, 120\/240\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe 5-2-1® Thermally Protected Surge Protection device is designed to protect HVAC equipment and other high end appliances from damaging electrical surges produced by proximity lightning strikes and other power line transients. Engineered using the latest in Thermally Protected Metal Oxide Varister (MOV) technology and independently tested to ensure superior protection and reliability for your customers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cb\u003eProtection For:  \u003c\/b\u003eAir Conditioners, Ductless Systems, Furnaces, Heat Pumps, Appliances, Motors and More.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePatented thermally protected MOV\u003c\/li\u003e\n\u003cli\u003eType 1 or 2 installations (\u003cem\u003eA\/C disconnect\u003c\/em\u003e, \u003cem\u003eJunction box\u003c\/em\u003e, \u003cem\u003eElectrical box\u003c\/em\u003e)\u003c\/li\u003e\n\u003cli\u003eNEMA 4X enclosure (Outdoor\/ Indoor use)\u003c\/li\u003e\n\u003cli\u003eDiagnostic indicator (Green LED [ON] = \u003cem\u003eDevice active\u003c\/em\u003e, Green LED [OFF] = \u003cem\u003eReplace device\u003c\/em\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum Surge Current:  100,000 Amps\u003c\/li\u003e\n\u003cli\u003eSPD Type:  1 or 2\u003c\/li\u003e\n\u003cli\u003eService Voltage (VAC):  120\/240 (single phase), 50 or 60 Hz\u003c\/li\u003e\n\u003cli\u003eNominal Discharge Current Rating:  20kA\u003c\/li\u003e\n\u003cli\u003eShort Circuit Rating (SCCR):  200kA\u003c\/li\u003e\n\u003cli\u003eMaximum Continuous Operating Voltage (MCOV):  150VAC L-N; 300VAC L-L\u003c\/li\u003e\n\u003cli\u003eVoltage Protection Rating (VPR):  600VAC L-N\/G; 1200VAC L-L\u003c\/li\u003e\n\u003cli\u003eOperating Temperature:  14°F (-10°C) to 122°F (50°C)\u003c\/li\u003e\n\u003cli\u003eDiagnostic Indicator:  Green LED (ON) Active Protection; Green LED (OFF) Replace Device\u003c\/li\u003e\n\u003cli\u003eApprovals:  UL 1449 4th Edition, ANSI, cUL\u003c\/li\u003e\n\u003cli\u003eEnclosure:  NEMA 4X\u003c\/li\u003e\n\u003cli\u003eInstallation:  Electrical Disconnect, Junction Box, Electrical Panel\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/res.cloudinary.com\/cps\/image\/upload\/productsheets\/tpspd_ps.pdf\"\u003eProduct Sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/res.cloudinary.com\/cps\/raw\/upload\/manuals\/tpspd_man.pdf\"\u003eManual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/7zQAhKQ2Xs0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"cursor: pointer; display: none;\" id=\"socialpilot-extension-hover-button\"\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":25644558385252,"sku":"TPSPD","price":79.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/products\/TPSPD-1_f4h6hj.jpg?v=1750462281"},{"product_id":"rectorseal-96415-rsh-50-surge-protective-device","title":"RectorSeal 96415 RSH-50 Surge Protective Device","description":"\u003ch1\u003eRectorSeal 96415 RSH-50 Surge Protective Device\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eRSH-50 Surge Protective Device (SPD) for Single-Phase System 120\/240 VAC Type 1\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLong-Lasting Gas Discharge Tube Technology\u003c\/li\u003e\n\u003cli\u003eTFMOV Technology\u003c\/li\u003e\n\u003cli\u003eLimited Lifetime Warranty\u003c\/li\u003e\n\u003cli\u003eGreen LED Easily Indicates Protection\u003c\/li\u003e\n\u003cli\u003eWeather-Rated under NEMA 4X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eDesigned to protect all single phase, 120\/240-V air conditioning, heat pumps and ductless mini-split systems (DMSS) from transient over-voltage and natural-cause surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eRecommended use:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFor residential or commercial use. Protects up to 50,000-amp single surges and up to 10,000-amp repetitive surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=OgAfRKMpp-8DYA104RWhnmEn4dRGnEl4IFRTBTHROz6~D~vDQqr-iuagZhyu4Xvz1hO1D9Da0juUzarZhGS~jArM0ImcVWiP0cVEb78pdwlwyrE8aGQOlfPtP2GGOcITY8zHNzJY7g3Gg9rNkzpJFa~avzcVwypjufjyzM9z7Rwmwx4cBZxKF4eN6NTaDB-av5tbsl6rNINrL56S6Of7nWnqPYedpXftm-9jdlUgn38M9ot13ReW3q7mQJtP7r9bZU7xW2T9w8LXrH8yfkB5MhPwkmkZTl2dYhvj1KBXT5hkQ5xMIyNl1PCpdnykUnHCxetKFJHYl8o-gg0dgu8QQw__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eRSH Series Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_88180004?Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfODgxODAwMDQiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=IhDVePzqIvgjtFc5YGAwrCULEP5Ahz1p2XIFFgsRmnR1yy83wv1RLOz1gVr1JuzLbsZIOw8E1Dr0ZKEZ0-~2aRUMECsKpg9E24Bf29jzl76U6CIJe6vB2EzNYv3zClhKzMiAfyL5oE8b8TdhohI7DYFdrQmC3-Z1KWd2NLyjQ4OCGPdZ59j0wuiuOKwZ4tbxldzZo5z2xQgoCN8f6gselRcH23giKW~7m1p~GtDvObfNqGc6qyK5Xi5a68bWUJre7Cf~45Odj-mnuaurT3zBu6N138JtW2GLgzozkVb5ZBKUjWr4Mn0ToZaE-Dgdg1cHzsJbLuZzbigFaQZ2uepIlQ__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eRSH Series Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/PnsGwpoouvY\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":43044477927640,"sku":"96415","price":96.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/products\/96415-rsh50-surge-protection-device-img-web.webp?v=1657285159"},{"product_id":"rectorseal-96420-voltage-range-monitor","title":"RectorSeal 96420 RSH-VRM60A Voltage Range Monitor","description":"\u003ch1\u003eRectorSeal 96420 \u003cspan data-mce-fragment=\"1\"\u003eRSH-VRM60A\u003c\/span\u003e Voltage Range Monitor\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe RSH-VRM60A is a Voltage Range Monitor that monitors the line protecting equipment against over and under voltage conditions. Protects equipment by monitoring the line protecting equipment against over and under voltage conditions that can cause damage to circuit boards and motors. The unit is fully programmable to set the voltage cutoff range from 90V to 300V while storing up to 300 events.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-info-main\"\u003e\n\u003cdiv class=\"product attribute description\"\u003e\n\u003cdiv class=\"value\"\u003e\n\u003cb\u003eFeatures\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eOver-Under Voltage Cutoff Delay can be adjusted from 0.5 to 60 Seconds\u003c\/li\u003e\n\u003cli\u003eLoad Restore Delay adjustable from 1 to 600 Seconds 120\/240 Single Phase, 60 Amp Double Pole Capacity Relays (handles loads 15-60 Amps)\u003c\/li\u003e\n\u003cli\u003eMagnetic Latching Relays for Maximum Reliability\u003c\/li\u003e\n\u003cli\u003eLarge Easy to Read LCD Digital Display with Dual Red and Green LED Diagnostics Indicators\u003c\/li\u003e\n\u003cli\u003eEasy Set Up, Field Programmable, No Laptop or Programming Tool Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=OgAfRKMpp-8DYA104RWhnmEn4dRGnEl4IFRTBTHROz6~D~vDQqr-iuagZhyu4Xvz1hO1D9Da0juUzarZhGS~jArM0ImcVWiP0cVEb78pdwlwyrE8aGQOlfPtP2GGOcITY8zHNzJY7g3Gg9rNkzpJFa~avzcVwypjufjyzM9z7Rwmwx4cBZxKF4eN6NTaDB-av5tbsl6rNINrL56S6Of7nWnqPYedpXftm-9jdlUgn38M9ot13ReW3q7mQJtP7r9bZU7xW2T9w8LXrH8yfkB5MhPwkmkZTl2dYhvj1KBXT5hkQ5xMIyNl1PCpdnykUnHCxetKFJHYl8o-gg0dgu8QQw__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eRSH Series Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_118385930?cache=1622145090\u0026amp;response-content-disposition=inline;filename=RSHVRM60A-96420-IM-R50366-0221-English_WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfMTE4Mzg1OTMwP2NhY2hlPTE2MjIxNDUwOTAmcmVzcG9uc2UtY29udGVudC1kaXNwb3NpdGlvbj1pbmxpbmU7ZmlsZW5hbWU9UlNIVlJNNjBBLTk2NDIwLUlNLVI1MDM2Ni0wMjIxLUVuZ2xpc2hfV0VCLnBkZiZyZXNwb25zZS1jb250ZW50LXR5cGU9YXBwbGljYXRpb24vcGRmIiwiQ29uZGl0aW9uIjp7IkRhdGVMZXNzVGhhbiI6eyJBV1M6RXBvY2hUaW1lIjoyMTQ3NDE0NDAwfX19XX0_\u0026amp;Signature=A6DcdQdY2rdZwF8JJapm~USIZXzWJEHt-f-Nhc~83xLh7s-RpJM3L~j2Aye1bNy7bEmRtfeD57EvRhTcQpg9yS407qJ4mz60A0oSPt~ppCpcuompZOHpfpVeyYE0QCeiCOh9oioplzYZHVAagsB-X1WzpDg3u1Is-mMUsfnJUMds~dhcnlNE9~XbXw~FZC-xTbWJGmueYd30pMMs3rzOKjLLvscTKBYwZbpT50hab3lvFKPLbgVQfJzPA8k60mH~f52YegqMu4Oah3kV4QjTORxwTh33wdxpWdOUH8rzu4O-0M9hKBhJCjvZvx6Uz8ZwOHhJYq6RUQkhSNNePI0uUQ__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eRSH Series Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/ex64aLWV-AM\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":43044498342104,"sku":"96420","price":185.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/products\/96420_rshvrm60a-img-1280web.webp?v=1657286859"},{"product_id":"rectorseal-96421-rsh-50-vrm-kit","title":"RectorSeal 96421 RSH-50 VRM KIT","description":"\u003ch1\u003eRectorSeal 96421 RSH-50 VRM KIT\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe RSH-50 VRM KIT combines the VRM60A and the RSH-50 in a NEMA 3R enclosure, for an all-in-one equipment solution. The RSH-50 uses Gas Discharge Tube (GDT) Technology along with Thermally Fused Metal Oxide Varistors (TMOV) for ultimate protection. Protects equipment from electrical surges and voltage disturbances by utilizing safety thermal fusing and gas discharge tube surge protection technology, combined with the ability to monitor the line protecting equipment against over and under voltage conditions that can cause damage to circuit boards and motors. The unit is fully programmable to set the voltage cutoff range from 90V to 300V while storing up to 300 events.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-info-main\"\u003e\n\u003cdiv class=\"product attribute description\"\u003e\n\u003cdiv class=\"value\"\u003e\n\u003cb\u003eFeatures\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eRSH-50 Surge Protector and Voltage Range Monitor inside a NEMA 4\/IP66 enclosure\u003c\/li\u003e\n\u003cli\u003eOver-Under Voltage Protection with Adjustable Auto Cut-Off and Auto Restore Delay Time; Over-Under Voltage Cutoff Delay can be adjusted from 0.5 to 60 Seconds; Load Restore Delay adjustable from 1 to 600 Seconds 120\/240 Single Phase.\u003c\/li\u003e\n\u003cli\u003eMagnetic Latching Relays for Maximum Reliability\u003c\/li\u003e\n\u003cli\u003eLarge Easy to Read LCD Digital Display with Dual Red and Green LED Diagnostics Indicators\u003c\/li\u003e\n\u003cli\u003eEasy Set Up, Field Programmable, No Laptop or Programming Tool Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=OgAfRKMpp-8DYA104RWhnmEn4dRGnEl4IFRTBTHROz6~D~vDQqr-iuagZhyu4Xvz1hO1D9Da0juUzarZhGS~jArM0ImcVWiP0cVEb78pdwlwyrE8aGQOlfPtP2GGOcITY8zHNzJY7g3Gg9rNkzpJFa~avzcVwypjufjyzM9z7Rwmwx4cBZxKF4eN6NTaDB-av5tbsl6rNINrL56S6Of7nWnqPYedpXftm-9jdlUgn38M9ot13ReW3q7mQJtP7r9bZU7xW2T9w8LXrH8yfkB5MhPwkmkZTl2dYhvj1KBXT5hkQ5xMIyNl1PCpdnykUnHCxetKFJHYl8o-gg0dgu8QQw__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eRSH Series Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_118386864?cache=1622145383\u0026amp;response-content-disposition=inline;filename=RSH50VRMKit-96421-IM-R50366-0221-English_WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfMTE4Mzg2ODY0P2NhY2hlPTE2MjIxNDUzODMmcmVzcG9uc2UtY29udGVudC1kaXNwb3NpdGlvbj1pbmxpbmU7ZmlsZW5hbWU9UlNINTBWUk1LaXQtOTY0MjEtSU0tUjUwMzY2LTAyMjEtRW5nbGlzaF9XRUIucGRmJnJlc3BvbnNlLWNvbnRlbnQtdHlwZT1hcHBsaWNhdGlvbi9wZGYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=igGG61qplA4FK-RTfidp6c56QRGfpdPWJCnZIoYgMAgk45B~XlrMbXnVI9rTwAlRGkEhIXyhCdbsQx6wqxsyeqQQftpCjMdQOL-K7snYkAm335Wilnda2hWAlmwHZ6lKcqec6sHldQ-CNVJ~~ibt-m2H-Mflh5iyyTJwM2~OxzmK882Bp3h78KAXPmiFukCftEeFtRqkewCeTKFkHDgCSHzg1T7dRRi6mAvl0G1Sc5D008ybvag9XQOnHigTZnj8iNFEqNvwm5jR1x~ta41H4WiJl-2Rhq5pCr-E4fG1ZNKaKQjGys3de6rqAvaAHPos-g~zVyEJKkOdtkNRZmfqZw__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eRSH Series Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_131307420?cache=1645820274\u0026amp;response-content-disposition=inline;filename=RSH50VRMKit-Homeowner-FLY-R50906-0222_PRINT.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfMTMxMzA3NDIwP2NhY2hlPTE2NDU4MjAyNzQmcmVzcG9uc2UtY29udGVudC1kaXNwb3NpdGlvbj1pbmxpbmU7ZmlsZW5hbWU9UlNINTBWUk1LaXQtSG9tZW93bmVyLUZMWS1SNTA5MDYtMDIyMl9QUklOVC5wZGYmcmVzcG9uc2UtY29udGVudC10eXBlPWFwcGxpY2F0aW9uL3BkZiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=O03R-hDHsUm~xggOxXneGB~A3PJc3Gp2ReCNmeVgEav9ar80FUdCk7A-S~OQgn2A1m4U3dewRBsdk-L3uSB8q2GFeyERJimze337G69bL1MSANI4Bw9s9gyU-LJv9estBr2bIQYXtuYppRl2yChKK46fHJy6UT1cHFjcSgaSs9DZWiT4P9KQGMPMFqZqfIkEmdGyEZ~C2hi7vfF4kgEW46vFnfvDNFPye1Mr-zhgzSaAthgUPYCyOPpnbK319pzFmBwm4GS6Svtqbmf7Jt6BO2c57dUWGuhwewTdlNlItZn~ZExhF0BXIkhMasZETq1y7nBXjuzac0G5Q4pM51ENVA__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eHomeowner Flyer\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Nwk0CVGXsR0\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":43044519968984,"sku":"96421","price":316.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/products\/rsh-96421_vrmkit-web-1280x1280_1.webp?v=1657288954"},{"product_id":"rectorseal-96419-rsh-50-with-60a-non-fused-disconnect-box","title":"RectorSeal 96419 RSH-50 with 60A Non-Fused Disconnect Box","description":"\u003ch1\u003eRectorSeal 96419 RSH-50 with 60A Non-Fused Disconnect Box\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eDisconnect Box with a pre-installed RSH-50 Surge Protector. Our RSH-50 is tabbed into the disconnect, to avoid any potential code violations with multiple wires being lugged in.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-info-main\"\u003e\n\u003cdiv class=\"product attribute description\"\u003e\n\u003ch3 class=\"value\"\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon Fused Disconnect Box\u003c\/li\u003e\n\u003cli\u003eLong-Lasting Gas Discharge Tube Technology\u003c\/li\u003e\n\u003cli\u003eTFMOV Technology\u003c\/li\u003e\n\u003cli\u003eGreen LED Easily Indicates Protection\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eDesigned to protect all single phase, 120\/240-V air conditioning, heat pumps and ductless mini-split systems (DMSS) from transient over-voltage and natural-cause surges.\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=OgAfRKMpp-8DYA104RWhnmEn4dRGnEl4IFRTBTHROz6~D~vDQqr-iuagZhyu4Xvz1hO1D9Da0juUzarZhGS~jArM0ImcVWiP0cVEb78pdwlwyrE8aGQOlfPtP2GGOcITY8zHNzJY7g3Gg9rNkzpJFa~avzcVwypjufjyzM9z7Rwmwx4cBZxKF4eN6NTaDB-av5tbsl6rNINrL56S6Of7nWnqPYedpXftm-9jdlUgn38M9ot13ReW3q7mQJtP7r9bZU7xW2T9w8LXrH8yfkB5MhPwkmkZTl2dYhvj1KBXT5hkQ5xMIyNl1PCpdnykUnHCxetKFJHYl8o-gg0dgu8QQw__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003e\u003cstrong\u003eRSH Series Brochure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_98756355?cache=1573243408\u0026amp;response-content-disposition=inline;filename%253DRSH50DB-NonFused-IM-R50366-1019_English_WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTg3NTYzNTU~Y2FjaGU9MTU3MzI0MzQwOCZyZXNwb25zZS1jb250ZW50LWRpc3Bvc2l0aW9uPWlubGluZTtmaWxlbmFtZSUyNTNEUlNINTBEQi1Ob25GdXNlZC1JTS1SNTAzNjYtMTAxOV9FbmdsaXNoX1dFQi5wZGYmcmVzcG9uc2UtY29udGVudC10eXBlPWFwcGxpY2F0aW9uL3BkZiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=ICEAsv6ZuHIRjiqo9H65YlkWmzixaKtOHbHUoWsItPsz7s8XfrYDwEd1SIqign1TLbh0FqoV2dZ512JVOGPTDEeiu6F9SLco9mQDbI7RqI17O5D-c9sJsKyf~2UWOi-WXhu97HdoF63jF6UyN94DVQEflojuqrqvWDXyCxUzNtt9ZWVSFupgEsvd-B0lsWygHdtz99elds2dhvCMdojE2jp8N7NkancDkeePMVi0Szc5sGYAzkNRs3M3wBOU4bvBxggUSsS4Pr3od6EpS~t5PNm2UzuWGszpKejXHWyvDh6z~AGEIt~R6OsfPZVDU92EzrDjge~11g6M6GMIIA3n4A__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eRSH Series Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_98290057_2?Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTgyOTAwNTdfMiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=bXjcrZJ8awjMYil0ANIglerfUjbj-zP-YlL~AJ4WWSYfg~-N6ZNWGoEbS5igQBwLoW28P5D5vSf7BEQgNsW8XSLhwYIUX9ALOKHmHj0xG2q-T61x-jbvZIO~0djtLO56a28QJ-Up-Q7yNpttjWTA7KZwOLqnoGt--KALlOAryMuuIAlNoZ0nz07FtWAJ6vyX4L3GZFwXdCZd82Iio57l26GhmWyd~szd7gJVec-CpeDP~Q6vznINhpFMqv0z~7ftCdaQUD5VYeSy~N1v4eMVxJCGfZE5C1UQN8hHHdpEVamhorn1Wg5Ce5KGSvDRyHfYzBtzBm3TeBeGiAWMS4ahgA__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eHomeowner Flyer\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/PnsGwpoouvY\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/R4pzP5FAldU\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":43231237570776,"sku":"96419","price":152.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/products\/96419-rsh50db60amp-nonfused-img-web.webp?v=1661897879"},{"product_id":"icm-controls-icm518-240-vac-split-phase-surge-protective-device","title":"ICM Controls ICM518 240 VAC Split Phase Surge Protective Device","description":"\u003ch1\u003eICM Controls ICM518 240 VAC Split Phase Surge Protective Device\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe ICM518 is a UL Listed Type 1\u0026amp;2  Whole Home Surge Protective Device for 240 VAC Split Phase configuration. When a surge occurs, the ICM518 will absorb the surge up to the limits expressed in the specifications section of this guide. The ICM518 incorporates thermal protection on the surge elements (TMOV’s) which allows for safe disabling of the surge protector when a surge exceeds the thermal limits of the device. A status light on the ICM518 identifies proper operational status when illuminated. The ICM518 can be installed as a Type 1 or Type 2 device for both indoor and outdoor applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p2\"\u003eType 1 or Type 2 Whole Home SPD\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eEasy 3-wire installation\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003e3\/4” conduit connection\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eGreen LED indicator tells whether the device is operational\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eLow cost, high performance\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eRugged and reliable\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eUL Listed\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eNEMA Type 4X watertight enclosure for indoor\/outdoor use\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003eSurge protection technology: Thermally protected MOVs (TFMOV)\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"s1\"\u003e\u003cb\u003eService voltage:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eSplit Phase 240 VAC\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShort Circuit Current Rating (SCCR):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e200 kA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNominal discharge current (In):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e20kA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum Surge Current:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e100,000 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSPD type:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eType 1 (Can also be used in Type 2 applications)\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSurge protection technology:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003eTFMOV\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProtection mode:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eL1-L2, L1-N, L2-N\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum Continuous Operation Voltage (MCOV):\u003c\/b\u003e L-L: 300VAC\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e L-N: 150VAC\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003e\n\u003cb\u003eInput power frequency:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e50\/60Hz\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eREPLACES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eASCO:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e420120S\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eEaton:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSP1-240S, SP2-240S\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eERICO (Critec):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTDX50C240\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eGenerac:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eG0073000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eIntermatic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAG2401C3, IG1200RC3, IG1240RC3, IG3240RC3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eLeviton:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e55240-ASA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eMARS:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e83905\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eSiemons:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTPS3A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/08\/ICM518-Sell-Sheet-2.pdf\"\u003eSell Sheet \u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/08\/ICM518-AG_LIAF247.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":43424862175448,"sku":"ICM518","price":97.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/products\/ICM518.png?v=1751287196"},{"product_id":"icm-controls-icm530-3-phase-surge-protective-device-delta-240vac-or-wye-120-208vac","title":"ICM Controls ICM530 3-Phase Surge Protective Device, Delta 240VAC or Wye 120\/208VAC","description":"\u003ch1\u003eICM Controls ICM530 3-Phase Surge Protective Device, Delta 240VAC or Wye 120\/208VAC\u003c\/h1\u003e\n\u003cp class=\"p2\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003eICM530 Series is 4 models\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eof Type 1 and Type 2 three-phase surge Protective Devices for three-phase Delta and three-phase Wye configurations.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eWhen a surge occurs, the ICM three-phase surge suppressor will absorb the surge up to the specified limitations of the device. ICM incorporates superior thermally protected metal oxide varistor technology into the three-phase surge suppressors, which allows for safe disabling of the surge elements when a surge exceeds the thermal limits of the device. There is a single status light on the controls which identifies operational status when illuminated.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe ICM 3-phase surge suppressors can be installed as a Type 1 or Type 2 device for both indoor and outdoor applications.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDelta or Wye Configuration\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eNEMA Type 4X watertight plastic enclosure for outdoor and indoor installation\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eGreen LED indicates surge protection present\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eEasily connects to electrical panel or disconnect for indoor and outdoor applications\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003eUL Listed Type 1 or Type 2 SPD\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eService voltage (3-Phase):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e240 VAC Delta or 120\/208 VAC Wye\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cb\u003eShort Circuit Current Rating (SCCR):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e200 kA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eNominal discharge current (In):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e20kA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eMaximum Surge Current:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e150,000 amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eProtection mode:\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p2\"\u003e3 for Delta configuration\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003e6 for Wye configuration (neutral tied to ground)\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eMaximum Continuous Operation Voltage (MCOV):\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p3\"\u003e\u003cspan class=\"s2\"\u003e\u003cb\u003eL-L:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e300 VAC\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"p2\"\u003e\n\u003cb\u003eL-N:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(for Wye configuration only): 150 VAC\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p3\"\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eVPR:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eDelta L-L:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1200 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eWye L-L:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1200 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eWye L-N:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e700 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p2\"\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSPD type:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eType 1 (can also be used in Type 2 applications)\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cb\u003eSurge protection technology:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003eTFMOV\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eInput power frequency:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e50\/60 Hz\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eREPLACES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eABB:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eOVRHLDxx-120\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eASCO:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e420120Y, 420240D\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eEaton:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eSP1-208Y, SP1-240D, SP2-208Y, SP2-240D\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eERICO (Critec):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eTDX50C120\/208, TDX50C120\/240D\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIntermatic:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eAG2083C3, L5F13Y1DG1\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eLeviton:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e55208-ASA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSiemens:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eTPS3D, TPS3C\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSquare D:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eSDSA2040, SDSA2040D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/08\/ICM530-Sell-Sheet-1.pdf\"\u003eSell Sheet \u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/08\/ICM530-AG_LIAF273.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/Nb_Zvkk-bX0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":43424896843992,"sku":"ICM530","price":184.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/products\/ICM530-_-Color.png?v=1750982457"},{"product_id":"icm-controls-icm531-3-phase-surge-protective-device-480vac-delta-or-277-480vac-wye","title":"ICM Controls ICM531 3-PHASE SURGE PROTECTIVE DEVICE, 480VAC (DELTA) OR 277\/480VAC (WYE)","description":"\u003ch1\u003eICM Controls ICM531 3-PHASE SURGE PROTECTIVE DEVICE, 480VAC (DELTA) OR 277\/480VAC (WYE)\u003c\/h1\u003e\n\u003cp class=\"p2\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003eICM530 Series is 4 models\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eof Type 1 and Type 2 three-phase surge Protective Devices for three-phase Delta and three-phase Wye configurations.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eWhen a surge occurs, the ICM three-phase surge suppressor will absorb the surge up to the specified limitations of the device. ICM incorporates superior thermally protected metal oxide varistor technology into the three-phase surge suppressors, which allows for safe disabling of the surge elements when a surge exceeds the thermal limits of the device. There is a single status light on the controls which identifies operational status when illuminated.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe ICM 3-phase surge suppressors can be installed as a Type 1 or Type 2 device for both indoor and outdoor applications.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDelta or Wye Configuration\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eNEMA Type 4X watertight plastic enclosure for outdoor and indoor installation\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eGreen LED indicates surge protection present\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eEasily connects to electrical panel or disconnect for indoor and outdoor applications\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003eUL Listed Type 1 or Type 2 SPD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eService voltage (3-Phase):\u003c\/b\u003e\u003cspan\u003e 480 VAC Delta or 277\/480 VAC Wye\u003cspan data-mce-fragment=\"1\" class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cb\u003eShort Circuit Current Rating (SCCR):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e200 kA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eNominal discharge current (In):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e20kA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eMaximum Surge Current:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e150,000 amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eProtection mode:\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p2\"\u003e3 for Delta configuration\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003e6 for Wye configuration (neutral tied to ground)\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eMaximum Continuous Operation Voltage (MCOV):\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p3\"\u003e\u003cspan class=\"s2\"\u003e\u003cb\u003eL-L:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e700 VAC\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"p2\"\u003e\n\u003cb\u003eL-N:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(for Wye configuration only): 350 VAC\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p3\"\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eVPR:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eDelta L-L:\u003c\/b\u003e\u003cspan\u003e 25\u003c\/span\u003e00 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eWye L-L:\u003c\/b\u003e\u003cspan\u003e 25\u003c\/span\u003e00 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eWye L-N:\u003c\/b\u003e\u003cspan\u003e 12\u003c\/span\u003e00 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p2\"\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSPD type:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eType 1 (can also be used in Type 2 applications)\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cb\u003eSurge protection technology:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003eTFMOV\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eInput power frequency:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e50\/60 Hz\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eREPLACES:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eABB:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eOVRHLDxx-277\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eASCO:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e420277Y, 420480D\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eEaton:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eSP1-480Y, SP1-480D, SP2-480Y, SP2-480D\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cb\u003eERICO (Critec):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003eTDX50C277\/480\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIntermatic:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eAG4803C3, L5F13Y2DG1\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eLeviton:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e55480-ASA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSiemens:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eTPS3E, TPS3F\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSquare D:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eSDSA2040, SDSA2040D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/08\/ICM531-Sell-Sheet-1.pdf\"\u003eSell Sheet \u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/08\/ICM531-AG_LIAF274.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/Nb_Zvkk-bX0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":43424961396952,"sku":"ICM531","price":189.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/products\/ICM531-_-Color.png?v=1750931257"},{"product_id":"icm-controls-icm532-3-phase-surge-protective-device-600vac-delta-or-347-600vac-wye","title":"ICM Controls ICM532 3-PHASE SURGE PROTECTIVE DEVICE, 600VAC (DELTA) OR 347\/600VAC (WYE)","description":"\u003ch1\u003eICM Controls ICM532 3-PHASE SURGE PROTECTIVE DEVICE, 600VAC (DELTA) OR 347\/600VAC (WYE)\u003c\/h1\u003e\n\u003cp class=\"p2\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003eICM530 Series is 4 models\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eof Type 1 and Type 2 three-phase surge Protective Devices for three-phase Delta and three-phase Wye configurations.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eWhen a surge occurs, the ICM three-phase surge suppressor will absorb the surge up to the specified limitations of the device. ICM incorporates superior thermally protected metal oxide varistor technology into the three-phase surge suppressors, which allows for safe disabling of the surge elements when a surge exceeds the thermal limits of the device. There is a single status light on the controls which identifies operational status when illuminated.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe ICM 3-phase surge suppressors can be installed as a Type 1 or Type 2 device for both indoor and outdoor applications.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDelta or Wye Configuration\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eNEMA Type 4X watertight plastic enclosure for outdoor and indoor installation\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eGreen LED indicates surge protection present\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eEasily connects to electrical panel or disconnect for indoor and outdoor applications\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003eUL Listed Type 1 or Type 2 SPD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eService voltage (3-Phase):\u003c\/b\u003e\u003cspan\u003e 600 VAC Delta or 347\/600VAC Wye\u003cspan data-mce-fragment=\"1\" class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cb\u003eShort Circuit Current Rating (SCCR):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e200 kA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eNominal discharge current (In):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e20kA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eMaximum Surge Current:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e150,000 amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eProtection mode:\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p2\"\u003e3 for Delta configuration\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003e6 for Wye configuration (neutral tied to ground)\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eMaximum Continuous Operation Voltage (MCOV):\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p3\"\u003e\u003cspan class=\"s2\"\u003e\u003cb\u003eL-L:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e920 VAC\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"p2\"\u003e\n\u003cb\u003eL-N:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e(for Wye configuration only): 460 VAC\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p3\"\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eVPR:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eDelta L-L:\u003c\/b\u003e\u003cspan\u003e 25\u003c\/span\u003e00 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eWye L-L:\u003c\/b\u003e\u003cspan\u003e 25\u003c\/span\u003e00 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eWye L-N:\u003c\/b\u003e\u003cspan\u003e 15\u003c\/span\u003e00 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p2\"\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSPD type:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eType 1 (can also be used in Type 2 applications)\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cb\u003eSurge protection technology:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003eTFMOV\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eInput power frequency:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e50\/60 Hz\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eREPLACES:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eASCO:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e420347Y, 420600D\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eEaton:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eSP1-600Y, SP1-600D, SP2-600Y\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cb\u003eERICO (Critec):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003eTDX50C347\/600\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIntermatic:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eAG6503, L5F13Y3DG1\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSiemens:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eTPS3L, TPS3G\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSquare D:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eSDSA3650, SDSA3650D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/08\/ICM532-Sell-Sheet-1.pdf\"\u003eSell Sheet \u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/08\/ICM532-AG_LIAF275.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Nb_Zvkk-bX0\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":43424977977560,"sku":"ICM532","price":152.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/products\/ICM532-_-Color.png?v=1751194139"},{"product_id":"icm-controls-icm532-3-phase-surge-protective-device-delta-high-leg-120-240-vac","title":"ICM Controls ICM533 3-PHASE SURGE PROTECTIVE DEVICE DELTA HIGH-LEG 120\/240 VAC","description":"\u003ch1\u003eICM Controls ICM533 3-PHASE SURGE PROTECTIVE DEVICE DELTA HIGH-LEG 120\/240 VAC\u003c\/h1\u003e\n\u003cp class=\"p2\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"s1\"\u003eICM530 Series is 4 models\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eof Type 1 and Type 2 three-phase surge Protective Devices for three-phase Delta and three-phase Wye configurations.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eWhen a surge occurs, the ICM three-phase surge suppressor will absorb the surge up to the specified limitations of the device. ICM incorporates superior thermally protected metal oxide varistor technology into the three-phase surge suppressors, which allows for safe disabling of the surge elements when a surge exceeds the thermal limits of the device. There is a single status light on the controls which identifies operational status when illuminated.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe ICM 3-phase surge suppressors can be installed as a Type 1 or Type 2 device for both indoor and outdoor applications.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDelta High-Leg Configuration\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eNEMA Type 4X watertight plastic enclosure for outdoor and indoor installation\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eGreen LED indicates surge protection present\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003eEasily connects to electrical panel or disconnect for indoor and outdoor applications\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003eUL Listed Type 1 or Type 2 SPD\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eService voltage (3-Phase):\u003c\/b\u003e\u003cspan\u003e 120\/240 VAC Delta High-Leg\u003cspan class=\"Apple-converted-space\" data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan class=\"Apple-converted-space\" data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cb\u003eShort Circuit Current Rating (SCCR):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e200 kA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eNominal discharge current (In):\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e20kA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eMaximum Surge Current:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e150,000 amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eProtection mode: \u003c\/b\u003e\u003c\/span\u003e3 for Delta configuration\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eMaximum Continuous Operation Voltage (MCOV):\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p3\"\u003e\u003cspan class=\"s2\"\u003e\u003cb\u003eL-L:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e300 VAC\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"p2\"\u003e\n\u003cb\u003eL-N:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e450 VAC\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003e\n\u003cstrong\u003e\u003cspan class=\"Apple-converted-space\"\u003eL-N: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"Apple-converted-space\"\u003e150VAC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p2\"\u003e\n\u003cstrong\u003e\u003cspan class=\"Apple-converted-space\"\u003eH-N: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"Apple-converted-space\"\u003e300 VAC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p3\"\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p3\"\u003e\u003cb\u003eVPR:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eL-L:\u003c\/b\u003e\u003cspan\u003e 12\u003c\/span\u003e00 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eH-L:\u003c\/b\u003e\u003cspan\u003e 15\u003c\/span\u003e00 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eL-N:\u003c\/b\u003e\u003cspan\u003e 7\u003c\/span\u003e00 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"p3\"\u003e\n\u003cstrong\u003eH-N: \u003c\/strong\u003e900 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"p2\"\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSPD type:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eType 1 (can also be used in Type 2 applications)\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cb\u003eSurge protection technology:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003eTFMOV\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eInput power frequency:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e50\/60 Hz\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eREPLACES:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eASCO:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e420240H\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eEaton:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eSPD050240H1\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eIntermatic:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eAG2403C3, L5F13D1DG1\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003cb\u003eSiemens:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003eTPS3B\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cspan class=\"s2\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eSquare D:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003eSDSA2040D\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/08\/ICM533-Sell-Sheet.pdf\"\u003eSell Sheet \u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2021\/08\/ICM533-AG_LIAF276.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Nb_Zvkk-bX0\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":43424983285976,"sku":"ICM533","price":165.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/products\/ICM533-_-Color.png?v=1750532407"},{"product_id":"rectorseal-69424-rsh-50-vrmdc-kit","title":"RectorSeal 96424 RSH-50 VRMDC KIT","description":"\u003ch1\u003eRectorSeal 96424 RSH-50 VRMDC KIT\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe RSH-50 VRMDC KIT combines the VRM60A, RSH-50, \u0026amp; 60A disconnect breaker in a NEMA 3R enclosure, for an all-in-one equipment solution. The RSH-50 uses Gas Discharge Tube (GDT) Technology along with Thermally Fused Metal Oxide Varistors (TMOV) for ultimate protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-info-main\"\u003e\n\u003cdiv class=\"product attribute description\"\u003e\n\u003cdiv class=\"value\"\u003e\n\u003cb\u003eFeatures\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eRSH-50 Surge Protector, Voltage Range Monitor, and 60A Disconnect Breaker inside a NEMA 3R\/IP66 enclosure\u003c\/li\u003e\n\u003cli\u003eOver-Under Voltage Protection with Adjustable Auto Cut-Off and Auto Restore Delay Time; Over-Under Voltage Cutoff Delay can be adjusted from 0.5 to 60 Seconds; Load Restore Delay adjustable from 1 to 600 Seconds 120\/240 Single Phase.\u003c\/li\u003e\n\u003cli\u003eMagnetic Latching Relays for Maximum Reliability\u003c\/li\u003e\n\u003cli\u003eLarge Easy to Read LCD Digital Display with Dual Red and Green LED Diagnostics Indicators\u003c\/li\u003e\n\u003cli\u003eEasy Set Up, Field Programmable, No Laptop or Programming Tool Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eProtects single phase equipment from electrical surges and voltage disturbances by utilizing safety thermal fusing and gas discharge tube surge protection technology, combined with the ability to monitor the line protecting equipment against over and under voltage conditions that can cause damage to circuit boards and motors. The unit includes a service disconnect and is fully programmable to set the voltage cutoff range from 90V to 300V while storing up to 300 events.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003eRecommended Use:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eResidential and Commercial Use, all single phase 120\/240V HVACR Equipment (air conditioning, heat pumps, mini-split applications)\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=OgAfRKMpp-8DYA104RWhnmEn4dRGnEl4IFRTBTHROz6~D~vDQqr-iuagZhyu4Xvz1hO1D9Da0juUzarZhGS~jArM0ImcVWiP0cVEb78pdwlwyrE8aGQOlfPtP2GGOcITY8zHNzJY7g3Gg9rNkzpJFa~avzcVwypjufjyzM9z7Rwmwx4cBZxKF4eN6NTaDB-av5tbsl6rNINrL56S6Of7nWnqPYedpXftm-9jdlUgn38M9ot13ReW3q7mQJtP7r9bZU7xW2T9w8LXrH8yfkB5MhPwkmkZTl2dYhvj1KBXT5hkQ5xMIyNl1PCpdnykUnHCxetKFJHYl8o-gg0dgu8QQw__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_142621949?cache=1677093785\u0026amp;response-content-disposition=inline;filename=RSH-50%2520VRMDC%2520KIT-IM-R50366-0223-WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfMTQyNjIxOTQ5P2NhY2hlPTE2NzcwOTM3ODUmcmVzcG9uc2UtY29udGVudC1kaXNwb3NpdGlvbj1pbmxpbmU7ZmlsZW5hbWU9UlNILTUwJTI1MjBWUk1EQyUyNTIwS0lULUlNLVI1MDM2Ni0wMjIzLVdFQi5wZGYmcmVzcG9uc2UtY29udGVudC10eXBlPWFwcGxpY2F0aW9uL3BkZiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=i0R-3oBsWR~XPaizqWxA5ByVmQf69uD0DYDzH9ncTmGcOYc4Gss1ubY3lFM326rTFF2nOEDvjfvmQkbYPosu13TLN0U3HyBE8FnoPe7rc3ecYoLEZp8uTzBUB155vNwOWH8ZCcSRcA0AIiHYf3S~yDFw79JGr~38ho4mKF3lkRzJULd9fjvZAQsMLYxwCY7xKP9cjaAmN~vXiMn-iA3Doia13QhlZGjKY2HrriElihKbkG8Z3eWzdz6qNfZzKHDhnCDS3-tZa~cpr2UHkUaabxn0JL3WnzmKzBQKp5vSfA7echfPuWkROJnDHOmgybb7TXW7FfBCyz2mx3-YIzpWpQ__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003eProduct Installation Instructions\u003c\/a\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_149938225?cache=1685126086\u0026amp;response-content-disposition=inline;filename=RSH-50%2520VRMDC%2520KIT%2520PDS-R50366-0523_English.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfMTQ5OTM4MjI1P2NhY2hlPTE2ODUxMjYwODYmcmVzcG9uc2UtY29udGVudC1kaXNwb3NpdGlvbj1pbmxpbmU7ZmlsZW5hbWU9UlNILTUwJTI1MjBWUk1EQyUyNTIwS0lUJTI1MjBQRFMtUjUwMzY2LTA1MjNfRW5nbGlzaC5wZGYmcmVzcG9uc2UtY29udGVudC10eXBlPWFwcGxpY2F0aW9uL3BkZiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=BuWwLhP9IC-apml4cv5jeIXQ1hnzxcgQwuX1VWaMKgQQdMJIs~PxKiaqPcJ~EYLVT7jnsrzRnHmvBKml8QzKQKHIN3wkUPyKoVFMLScTnLMF3X8Osyp~xHR6qULeQjDvm-ry39NhOWUt4pYuLZKkecznWigJI3vPz5w82E~QqxwF7yfeYQHoQDLOQS~CQYzE~8L3zsJfPGqy7Z3zrRsMvXXOpPmoJevGsPAfdyndeEQN-djr7lfuJD9yp0AYSjshDSXN~6DCiKt71o3WWUFygYcQ3bwbDxCPQ2rsHyo5G-sAl0Rp4v2zSxZRwPJVHLkChRYAfxt93UOrR7WgLrwjiQ__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003eProduct Data Sheet\u003c\/a\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_131307424?cache=1683751842\u0026amp;response-content-disposition=inline;filename=RSH50VRMKit-Homeowner-FLY-R50906-0523-WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfMTMxMzA3NDI0P2NhY2hlPTE2ODM3NTE4NDImcmVzcG9uc2UtY29udGVudC1kaXNwb3NpdGlvbj1pbmxpbmU7ZmlsZW5hbWU9UlNINTBWUk1LaXQtSG9tZW93bmVyLUZMWS1SNTA5MDYtMDUyMy1XRUIucGRmJnJlc3BvbnNlLWNvbnRlbnQtdHlwZT1hcHBsaWNhdGlvbi9wZGYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=nU13WAW02GFXyeuYpuq7rYFIvoYx-14NQPTV3TvVoR~EXMicQEushnutUm~vJaRj-sT8bdUNIqyzgTUtQDK3tUNjpLGiaU5PIsq1ic74ATZVTIpyOpcSzjfV~oCNd9tZu5-l~nOVo63lIzdIDZdKF~t1s9W7BtkBZCkchVsor6W9uSWi2AqN9MNIbkcd0UHeWoM9xhpeFzVscenP8YO-KvMsubcgzQcEP9IKPhZX2L-fUerWKvCzrnvUYgQmZzakOHRI7ad4hFewSPzcjz5bI-u5MjTxxRycfhGveCQLkZatzH~WRLSbehAh-RWQfMDADnV-jbLypVuee6bJ9EC5pQ__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003eProduct Flyer\u003c\/a\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?cache=1683751786\u0026amp;response-content-disposition=inline;filename=RSH-ProductCatlog-CAT-R50366-0523-WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDY~Y2FjaGU9MTY4Mzc1MTc4NiZyZXNwb25zZS1jb250ZW50LWRpc3Bvc2l0aW9uPWlubGluZTtmaWxlbmFtZT1SU0gtUHJvZHVjdENhdGxvZy1DQVQtUjUwMzY2LTA1MjMtV0VCLnBkZiZyZXNwb25zZS1jb250ZW50LXR5cGU9YXBwbGljYXRpb24vcGRmIiwiQ29uZGl0aW9uIjp7IkRhdGVMZXNzVGhhbiI6eyJBV1M6RXBvY2hUaW1lIjoyMTQ3NDE0NDAwfX19XX0_\u0026amp;Signature=T~2b1OsLUQFYe2RyLFSaTW~zbfNvq2rzadxbT6Pd8A4gUu8y6HFqkSZiqBZhQZRrJbnKfNS2lWxjCPjREEEM4-585M2AY5VUcQsxm6fQsknSgt6QBb6sgFFDbWo-W~a9KOok-Geac9fjnTfFuUmFtSrg5LoXl45DZuoDn9scM3hv6iPUyU1~IRsNl7JxksUGLPMSZPL3PYb0lSAV6soO4FoeJ8jzJIo~SzBGQWV4gWlBjq9-N~1QN1zkylohB8tyOYxiaccNg~-kR~Jl-XeTv5zQBZ0-i5Fp3NfCz-P5N7EFzd9dBqEy3lrBzhPRaA6M2oinlqSYl5MRO~WsIw2SEw__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003eRSH Series Brochure\u003c\/a\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/VYVdqHjo0Uo\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":43913615671512,"sku":"96424","price":442.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/96424.png?v=1751417310"},{"product_id":"icm-controls-icm495-60a-60-amp-disconnect-with-internal-surge-protection-non-fused","title":"ICM Controls ICM495-60A 60 Amp Disconnect with Internal Surge Protection (Non Fused)","description":"\u003ch1\u003eICM Controls ICM495-60A 60 Amp Disconnect with Internal Surge Protection (Non Fused)\u003c\/h1\u003e\n\u003cdiv\u003e\u003cspan\u003eThe ICM495 is a UL Listed Electrical Disconnect with an Internal Surge Protective Device built-in. The ICM495 is available in two models 30A Fused and 60A Non Fused. The included Surge Protective Device is intended for 120VAC Single-Phase or 240VAC Split-Phase configurations. Designed to protect equipment from transient surges. The ICM495 is a great low cost option to protect some of the most valuable equipment on the property, including: Air conditioning units, heat pumps, mini-split systems, pool \u0026amp; spa equipment and more…\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli class=\"li1\"\u003eUL Listed Electrical Disconnect including both enclosure \u0026amp; surge protector\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e120VAC single-phase, 240VAC split-phase\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eFeatures an internal surge protective device\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eMaximum Surge Current Rating of 100kA\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eHighest UL rating for nominal discharge current (in 20kA), for increased longevity \u0026amp; durability of the SPD\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eConstructed with 2 high-quality thermally protected MOV’s (TFMOV)\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eCompletely factory wired for quick and easy installation\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eNEMA type 3R rated powder coated metal enclosure for indoor\/outdoor use\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eFully accessible mounting holes, no\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"yKMVIe\" role=\"heading\" aria-level=\"1\"\u003edisassembling\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003erequired\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eBraided strap thoroughly grounding both the enclosure and cover\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eLED indicator light showing when surge protection is operational\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e30A Fused \u0026amp; 60A non-fused models available\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eMade in the USA\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eProtects Against:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLightning strikes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower outages \u0026amp; recoveries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDowned power lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStartup of larger equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEquipment failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort circuits and more...\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eService Voltage:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSplit Phase 240 VAC; 30A at -40°C min. and 25°C max., 240 VAC; 25A at -40°C min. and 55°C max., 240VAC; 60A at -40°C min. and 55°C max.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Current Rating (SCCR):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Surge Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 kA (single event)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Discharge Current (In):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 kA (15 multiple events)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPD Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eType 2 applications only\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Protection Technology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTFMOV\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eL1-L2, L1-G, L2-G\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Continuous Operation Voltage (MCOV):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eL-L: 300 VAC, L-G: 150 VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVPR (Vpk):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMode: L-L = 1200, L-N = 700\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power Frequency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\/60 Hz\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGreen LED indicates surge protection present\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNEMA\/Type 3R metal enclosure for outdoor and indoor installation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Point:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLocated within sight of the motor controller\/equipment\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e9.0” L x 5.25” W x 2.50” D\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°F to 131°F (-40°C to 55°C)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLess than 85%, non-condensing\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLess than 2000 meters\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Certification and Approvals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eANSI\/UL1449 5th Edition cULus Listed Device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREPLACES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll standard disconnect boxes rated for equal voltage and current configurations:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e30A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– MARS: 83916, RectorSeal: 96417 w\/ RSH-50\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e60A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– MARS: 83915, RectorSeal: 96419 w\/ RSH-50\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2022\/10\/ICM495-30A-30A_LIS508.pdf\"\u003eSell Sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2022\/10\/ICM495-30A-60A-LIAF319-1.pdf\"\u003e Installation Guide\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":43925472608472,"sku":"ICM495-60A","price":104.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/ICM495-30A-60A-wSPD_color-705x662.png?v=1750986210"},{"product_id":"rectorseal-96414-rsh-120-surge-protective-device-120ka","title":"RectorSeal 96414 RSH-120 Surge Protective Device, 120kA","description":"\u003ch1\u003eRectorSeal 96414 RSH-120 Surge Protective Device, 120kA\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe RSH-120 is a surge protector for the entire home, and is meant to be installed at the breaker panel. The RSH-120 uses Gas Discharge Tube Technology along with Thermally-Fused Metal Oxide Varistors for ultimate protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to protect electrical appliances in the home from damaging power surges and spikes\u003c\/li\u003e\n\u003cli\u003eDual Diagnostic LEDs and audible alarm\u003c\/li\u003e\n\u003cli\u003eGas Discharge Tube Technology and TMOVs\u003c\/li\u003e\n\u003cli\u003eType 1 SPD, NEMA 4X and IP66 rated\u003c\/li\u003e\n\u003cli\u003eLimited Lifetime Product warranty\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned to protect the entire home from transient over-voltage and natural-cause surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eInstall at breaker box to protect whole home from transient power surges that can cause system lock-up and malfunctions, faulty output, corrupted files, equipment failure and long-term degradation of devices and equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProtects up to 120,000-amp single surges and up to 20,000-amp repetitive surges\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eType 1 Device - can be mounted anywhere in the electrical system\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended use:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eResidential and commercial  use\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAll single-phase 120\/240 VAC indoor facility breaker panel installation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage - 120\/240VAC\u003c\/li\u003e\n\u003cli\u003eMax discharge current per phase - 120kA (1 hit survivability)\u003c\/li\u003e\n\u003cli\u003eNominal discharge current -  20kA (15 hits survivability)\u003c\/li\u003e\n\u003cli\u003eShort circuit  current - 200kA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=OgAfRKMpp-8DYA104RWhnmEn4dRGnEl4IFRTBTHROz6~D~vDQqr-iuagZhyu4Xvz1hO1D9Da0juUzarZhGS~jArM0ImcVWiP0cVEb78pdwlwyrE8aGQOlfPtP2GGOcITY8zHNzJY7g3Gg9rNkzpJFa~avzcVwypjufjyzM9z7Rwmwx4cBZxKF4eN6NTaDB-av5tbsl6rNINrL56S6Of7nWnqPYedpXftm-9jdlUgn38M9ot13ReW3q7mQJtP7r9bZU7xW2T9w8LXrH8yfkB5MhPwkmkZTl2dYhvj1KBXT5hkQ5xMIyNl1PCpdnykUnHCxetKFJHYl8o-gg0dgu8QQw__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eRSH Series Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/bit.ly\/3vSsoIp\"\u003e\u003cspan\u003eRSH Series Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/N7McbsVCrnY?si=QbKdGubzvCTIFWCx\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":45209075810520,"sku":"96414","price":244.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/Screenshot2024-07-02084156.png?v=1750731438"},{"product_id":"rectorseal-96416-rsh-60-surge-protective-device-60ka","title":"RectorSeal 96416 RSH-60 Surge Protective Device, 60kA","description":"\u003ch1\u003eRectorSeal 96416 RSH-60 Surge Protective Device, 60kA\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eRSH-60 Surge Protective Device (SPD) for Single-Phase System 120\/240 VAC Type 1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLong-Lasting Gas Discharge Tube Technology\u003c\/li\u003e\n\u003cli\u003eTFMOV Technology\u003c\/li\u003e\n\u003cli\u003eLimited Lifetime Warranty\u003c\/li\u003e\n\u003cli\u003eGreen LED Easily Indicates Protection\u003c\/li\u003e\n\u003cli\u003eWeather-Rated under NEMA 4X\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned to protect all single phase, 120\/240-V air conditioning, heat pumps and ductless mini-split systems (DMSS) from transient over-voltage and natural-cause surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtect HVAC equipment from electrical surges\u003c\/li\u003e\n\u003cli\u003eProtects from up to 60,000-amp single surges and up to 20,000-amp repetitive surges\u003c\/li\u003e\n\u003cli\u003eType 1 Device - can be mounted anywhere in the electrical system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended use:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eResidential and commercial  use.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAll single-phase 120\/240 VAC outside condensing units and indoor air handlers.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage - 120\/240VAC\u003c\/li\u003e\n\u003cli\u003eMax discharge current per phase - 60kA (1 hit survivability)\u003c\/li\u003e\n\u003cli\u003eNominal discharge current -  20kA (15 hits survivability)\u003c\/li\u003e\n\u003cli\u003eShort circuit  current - 200kA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=OgAfRKMpp-8DYA104RWhnmEn4dRGnEl4IFRTBTHROz6~D~vDQqr-iuagZhyu4Xvz1hO1D9Da0juUzarZhGS~jArM0ImcVWiP0cVEb78pdwlwyrE8aGQOlfPtP2GGOcITY8zHNzJY7g3Gg9rNkzpJFa~avzcVwypjufjyzM9z7Rwmwx4cBZxKF4eN6NTaDB-av5tbsl6rNINrL56S6Of7nWnqPYedpXftm-9jdlUgn38M9ot13ReW3q7mQJtP7r9bZU7xW2T9w8LXrH8yfkB5MhPwkmkZTl2dYhvj1KBXT5hkQ5xMIyNl1PCpdnykUnHCxetKFJHYl8o-gg0dgu8QQw__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eRSH Series Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/prod-originals.webdamdb.com\/orig\/13771_97992267?sign=1\u0026amp;si=zz543L5nwESTNGFR_pA5m3VKRGwrZkg3UURXQzg4V0F6VVlmeUxVeEQ4NFNOaXN3dm5Fa2p4cTRZd0VJNkprYkp4eWtRYjFhaHRWVXJsN0g0emY4WlQzRTYzblFoNlcvSTFMaGRkQ2pWUEM0Q3lrU1ZPemZ4cEF5d0RkNmdPckMwSVhFTlVYMXpwWG5FUVlzWnRVRHBqRndSeE1mcUFHeDlMLzNOWkpLT0NXR0YzYWJtaHZnV1N4UFNzVHVYTER4L255VWNzb2Y5QTU2ZVFMMFZNaDlvVGtiQWZiV080UTdlQW9XYlZHWStyRytUM3pEa2xwQ3NwUVg\u0026amp;h=MmE1Mzg2NWE0YTI2MGFhODhmOWU5MWZjYmRhNzVkYmQ0MmQ0OWRlZThkMThkOGQ4M2M1NTFmNTA5ODA4MmUwYg\"\u003e\u003cspan\u003eRSH Series Instructions\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/PnsGwpoouvY?si=oVmZQ8hpzLcdFnx7\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":45209690964184,"sku":"96416","price":187.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/Screenshot2024-07-02130238.png?v=1750585774"},{"product_id":"rectorseal-96418-rsh-50-with-60a-fused-disconnect-box","title":"RectorSeal 96418 RSH-50 with 60A Fused Disconnect Box","description":"\u003ch1\u003eRectorSeal 96418 RSH-50 with 60A Fused Disconnect Box\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor residential or commercial use. Protects up to 50,000-amp single surges and up to 10,000-amp repetitive surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDisconnect Box with a pre-installed RSH-50 Surge Protector. Our RSH-50 is tabbed into the disconnect, to avoid any potential code violations with multiple wires being lugged in.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-info-main\"\u003e\n\u003cdiv class=\"product attribute description\"\u003e\n\u003ch3 class=\"value\"\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFused Disconnect Box\u003c\/li\u003e\n\u003cli\u003eLong-Lasting Gas Discharge Tube Technology\u003c\/li\u003e\n\u003cli\u003eTFMOV Technology\u003c\/li\u003e\n\u003cli\u003eGreen LED Easily Indicates Protection\u003c\/li\u003e\n\u003cli\u003eDesigned to protect all single phase, 120\/240-V air conditioning, heat pumps and ductless mini-split systems (DMSS) from transient over-voltage and natural-cause surges.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?cache=1595253040\u0026amp;response-content-disposition=inline;filename%253DRSH-SurgeProtector-FLY-R50366-0720web.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDY~Y2FjaGU9MTU5NTI1MzA0MCZyZXNwb25zZS1jb250ZW50LWRpc3Bvc2l0aW9uPWlubGluZTtmaWxlbmFtZSUyNTNEUlNILVN1cmdlUHJvdGVjdG9yLUZMWS1SNTAzNjYtMDcyMHdlYi5wZGYmcmVzcG9uc2UtY29udGVudC10eXBlPWFwcGxpY2F0aW9uL3BkZiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=AjXaKf6DL19TCv3gRJ08PxVAkoiktkLMcpVfG3hOvnxM6Hs-vpAgE9KA7BdLBY4JKrxSntsBvtVNY3cDb66c5b6QJi87iq6qAqiv4PiRdk7u0IQnSwwTu-4tF5rjodpE4kKqeKX0~xfTqJn~U7~APbUhJhO7K1IRc~VmLBscCYLNcvBrX8mADmn~32-94F5kNemUk4NjWcF~jZYbxu3dD1nvZTyTgXBus~Bq9GidSQ~Vzbu8b7eEKdg8jY6wb4LTILco~usH4-9zcHtrRkGvTKo~lm6Gyy08KiG7GczmYgaN9IV4UwO1xeA4w0jm92gg9CvAVegwStX~iuHSK0js3A__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan mce-data-marked=\"1\"\u003e\u003cstrong\u003eRSH Series Brochure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_98290057_2?Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTgyOTAwNTdfMiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=bXjcrZJ8awjMYil0ANIglerfUjbj-zP-YlL~AJ4WWSYfg~-N6ZNWGoEbS5igQBwLoW28P5D5vSf7BEQgNsW8XSLhwYIUX9ALOKHmHj0xG2q-T61x-jbvZIO~0djtLO56a28QJ-Up-Q7yNpttjWTA7KZwOLqnoGt--KALlOAryMuuIAlNoZ0nz07FtWAJ6vyX4L3GZFwXdCZd82Iio57l26GhmWyd~szd7gJVec-CpeDP~Q6vznINhpFMqv0z~7ftCdaQUD5VYeSy~N1v4eMVxJCGfZE5C1UQN8hHHdpEVamhorn1Wg5Ce5KGSvDRyHfYzBtzBm3TeBeGiAWMS4ahgA__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan mce-data-marked=\"1\"\u003eHomeowner Flyer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan mce-data-marked=\"1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/PnsGwpoouvY\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/R4pzP5FAldU\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":45391350530264,"sku":"96418","price":155.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/96418-rsh50db60amp-fused-img-web_1.webp?v=1724517927"},{"product_id":"rectorseal-96417-rsh-20-motor-surge-protector-x-13","title":"RectorSeal 96427 RSH-20 Motor Surge Protector, X-13","description":"\u003ch1\u003eRectorSeal 96427 RSH-20 Motor Surge Protector, X-13\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eRSH-20MP-X13 Surge Protective Device (SPD) for Single-Phase 120\/240 VAC Indoor X-13 \u0026amp; Evergreen Motors\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Recognized\u003c\/li\u003e\n\u003cli\u003eThermally Fused MOVs\u003c\/li\u003e\n\u003cli\u003e5 Year Limited Product Warranty\u003c\/li\u003e\n\u003cli\u003ePlug-n-Play for Ease of Installation\u003c\/li\u003e\n\u003cli\u003eDiagnostic LED indicates Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProtects single phase 120\/240V X-13 \u0026amp; Evergreen ECM indoor blower motors from transient over-voltage and natural-cause surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended for \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResidential and Commercial Use, all single-phase 120\/240V ECM indoor motors: X-13\/\"X\" Style, 5-PIN, Ensite, and Azure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage – 120\/240 VAC\u003c\/li\u003e\n\u003cli\u003eMax discharge current per phase – 20kA (1 hit\u003cbr\u003esurvivability)\u003c\/li\u003e\n\u003cli\u003eNominal discharge current – 5kA (15 hits\u003cbr\u003esurvivability)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Recognized\u003c\/li\u003e\n\u003cli\u003eThermally Fused MOV Technology for safety \u0026amp; performance\u003c\/li\u003e\n\u003cli\u003eLimited 5 year warranty \u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003e3 modes of protection: L-G, \u003c\/span\u003eN-G, L-N\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003ePlug-n-Play for ease of \u003c\/span\u003einstallation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003eDiagnostic LED indicates \u003c\/span\u003eprotection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_156630584?cache=1709730706\u0026amp;response-content-disposition=inline;filename=RSH-20MP_CrossReferenceSheet_R51137_0224WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfMTU2NjMwNTg0P2NhY2hlPTE3MDk3MzA3MDYmcmVzcG9uc2UtY29udGVudC1kaXNwb3NpdGlvbj1pbmxpbmU7ZmlsZW5hbWU9UlNILTIwTVBfQ3Jvc3NSZWZlcmVuY2VTaGVldF9SNTExMzdfMDIyNFdFQi5wZGYmcmVzcG9uc2UtY29udGVudC10eXBlPWFwcGxpY2F0aW9uL3BkZiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=FFX19NvGaQSxPQXEHMsYm8fqNA3B1CLKn-ZljDpcsmdsRk8O-TvPsKSBSh2a5nYUquuCYC1KDaSmeG6oPF-IeNRfV8BXFdDcQctbnA5tRHgd9r-echEyzVYxCbCdO6He4ndMCPtdgXUbr1o9LSz0TTIAn8RovgUfFuHwKJg1PAucpm71W1ZYJO906rVg4~apWSAUE285yfEq8uvw3EILGeWo9AdGo5lsHzBcavlSxDWXiYGHEdO8yjwlAACR66B2U8NzH~LLWCW418p9y4IGeikzepj-cZWDvkwRwb5BJNdg-vxUQrUtucXUZsjhXvtHBKJqPHvrhj2Rk4MpojTMGA__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cstrong\u003eCross Reference Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?cache=1710343735\u0026amp;response-content-disposition=inline;filename=RSH-ProductCatlog-CAT-R50366-0124WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDY~Y2FjaGU9MTcxMDM0MzczNSZyZXNwb25zZS1jb250ZW50LWRpc3Bvc2l0aW9uPWlubGluZTtmaWxlbmFtZT1SU0gtUHJvZHVjdENhdGxvZy1DQVQtUjUwMzY2LTAxMjRXRUIucGRmJnJlc3BvbnNlLWNvbnRlbnQtdHlwZT1hcHBsaWNhdGlvbi9wZGYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=PMR6aaUbpSSib0IK0bJwgMV9BDEMUtRRoUN2NLs~OAjDBPV2r-PEFydiJIknG896fQFs4Z2aaMaWWa~rf8PrN~EiOtlnSF4OuGwaMWPsTnbLAf7kjzX6xmZe5nkDFvWEaVI0NrAgijXtOorJ5Ijs-gKdj0MwJLZ8Anq-1dJi5AOlTa~XC~HLwMLnJHPXL9foQhunrZ6iVKLfzOiBqWmFJ-TvUa2Mo0issEMjlrokTOGgKOx3g03Y92EvW6wBhyMvcpVPC10Vv4tN4QufhEuh3w6jae7HZMT7ofoFGJna3F762I9QNXhL21OYK9UHs0wfJayJBEsV0kneJ2WFu5Z~4g__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan mce-data-marked=\"1\"\u003eRSH Series Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Gj_5SuBv8PM?si=rb7Hsr1DZ0OC9HmJ\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":45395269845208,"sku":"96427","price":50.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/1280_Im1oIq32C711oFRk.webp?v=1724626144"},{"product_id":"rectorseal-96428-rsh-20-motor-surge-protector-5-pin","title":"RectorSeal 96428 RSH-20 Motor Surge Protector, 5-Pin","description":"\u003ch1\u003eRectorSeal 96428 RSH-20 Motor Surge Protector, 5-Pin\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eRSH-20MP-5P Surge Protective Device (SPD) for Single-Phase 120\/240 VAC Indoor 5-Pin Motors\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Recognized\u003c\/li\u003e\n\u003cli\u003eThermally Fused MOVs\u003c\/li\u003e\n\u003cli\u003e5 Year Limited Product Warranty\u003c\/li\u003e\n\u003cli\u003ePlug-n-Play for Ease of Installation\u003c\/li\u003e\n\u003cli\u003eDiagnostic LED indicates Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProtects single phase 120\/240V 5-Pin ECM indoor blower motors from transient over-voltage and natural-cause surges.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended for \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFor single phase 120\/240 VAC ECM 5-Pin indoor motors\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage – 120\/240 VAC\u003c\/li\u003e\n\u003cli\u003eMax discharge current per phase – 20kA (1 hit\u003cbr\u003esurvivability)\u003c\/li\u003e\n\u003cli\u003eNominal discharge current – 5kA (15 hits\u003cbr\u003esurvivability)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Recognized\u003c\/li\u003e\n\u003cli\u003eThermally Fused MOV Technology for safety \u0026amp; performance\u003c\/li\u003e\n\u003cli\u003eLimited 5 year warranty \u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003e3 modes of protection: L-G, \u003c\/span\u003eN-G, L-N\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003ePlug-n-Play for ease of \u003c\/span\u003einstallation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003eDiagnostic LED indicates \u003c\/span\u003eprotection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_156630584?cache=1709730706\u0026amp;response-content-disposition=inline;filename=RSH-20MP_CrossReferenceSheet_R51137_0224WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfMTU2NjMwNTg0P2NhY2hlPTE3MDk3MzA3MDYmcmVzcG9uc2UtY29udGVudC1kaXNwb3NpdGlvbj1pbmxpbmU7ZmlsZW5hbWU9UlNILTIwTVBfQ3Jvc3NSZWZlcmVuY2VTaGVldF9SNTExMzdfMDIyNFdFQi5wZGYmcmVzcG9uc2UtY29udGVudC10eXBlPWFwcGxpY2F0aW9uL3BkZiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=FFX19NvGaQSxPQXEHMsYm8fqNA3B1CLKn-ZljDpcsmdsRk8O-TvPsKSBSh2a5nYUquuCYC1KDaSmeG6oPF-IeNRfV8BXFdDcQctbnA5tRHgd9r-echEyzVYxCbCdO6He4ndMCPtdgXUbr1o9LSz0TTIAn8RovgUfFuHwKJg1PAucpm71W1ZYJO906rVg4~apWSAUE285yfEq8uvw3EILGeWo9AdGo5lsHzBcavlSxDWXiYGHEdO8yjwlAACR66B2U8NzH~LLWCW418p9y4IGeikzepj-cZWDvkwRwb5BJNdg-vxUQrUtucXUZsjhXvtHBKJqPHvrhj2Rk4MpojTMGA__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cstrong\u003eCross Reference Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?cache=1710343735\u0026amp;response-content-disposition=inline;filename=RSH-ProductCatlog-CAT-R50366-0124WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDY~Y2FjaGU9MTcxMDM0MzczNSZyZXNwb25zZS1jb250ZW50LWRpc3Bvc2l0aW9uPWlubGluZTtmaWxlbmFtZT1SU0gtUHJvZHVjdENhdGxvZy1DQVQtUjUwMzY2LTAxMjRXRUIucGRmJnJlc3BvbnNlLWNvbnRlbnQtdHlwZT1hcHBsaWNhdGlvbi9wZGYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=PMR6aaUbpSSib0IK0bJwgMV9BDEMUtRRoUN2NLs~OAjDBPV2r-PEFydiJIknG896fQFs4Z2aaMaWWa~rf8PrN~EiOtlnSF4OuGwaMWPsTnbLAf7kjzX6xmZe5nkDFvWEaVI0NrAgijXtOorJ5Ijs-gKdj0MwJLZ8Anq-1dJi5AOlTa~XC~HLwMLnJHPXL9foQhunrZ6iVKLfzOiBqWmFJ-TvUa2Mo0issEMjlrokTOGgKOx3g03Y92EvW6wBhyMvcpVPC10Vv4tN4QufhEuh3w6jae7HZMT7ofoFGJna3F762I9QNXhL21OYK9UHs0wfJayJBEsV0kneJ2WFu5Z~4g__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan mce-data-marked=\"1\"\u003eRSH Series Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Gj_5SuBv8PM?si=rb7Hsr1DZ0OC9HmJ\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":49124206411992,"sku":"96428","price":50.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/96428.png?v=1750597419"},{"product_id":"rectorseal-96429-rsh-20-motor-surge-protector-ensite","title":"RectorSeal 96429 RSH-20 Motor Surge Protector, Ensite - Edmondson Supply","description":"\u003ch1\u003eRectorSeal 96429 RSH-20 Motor Surge Protector, Ensite\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eRSH-20MP-EN Surge Protective Device (SPD) for Single-Phase 120\/240 VAC Indoor Ensite Motors\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Recognized\u003c\/li\u003e\n\u003cli\u003eThermally Fused MOVs\u003c\/li\u003e\n\u003cli\u003e5 Year Limited Product Warranty\u003c\/li\u003e\n\u003cli\u003ePlug-n-Play for Ease of Installation\u003c\/li\u003e\n\u003cli\u003eDiagnostic LED indicates Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProtects single phase 120\/240V Ensite ECM indoor blower motors from transient over-voltage and natural-cause surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended for \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFor single phase 120\/240 VAC ECM Ensite indoor motors\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage – 120\/240 VAC\u003c\/li\u003e\n\u003cli\u003eMax discharge current per phase – 20kA (1 hit\u003cbr\u003esurvivability)\u003c\/li\u003e\n\u003cli\u003eNominal discharge current – 5kA (15 hits\u003cbr\u003esurvivability)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Recognized\u003c\/li\u003e\n\u003cli\u003eThermally Fused MOV Technology for safety \u0026amp; performance\u003c\/li\u003e\n\u003cli\u003eLimited 5 year warranty \u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003e3 modes of protection: L-G, \u003c\/span\u003eN-G, L-N\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003ePlug-n-Play for ease of \u003c\/span\u003einstallation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003eDiagnostic LED indicates \u003c\/span\u003eprotection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_156630584?cache=1709730706\u0026amp;response-content-disposition=inline;filename=RSH-20MP_CrossReferenceSheet_R51137_0224WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfMTU2NjMwNTg0P2NhY2hlPTE3MDk3MzA3MDYmcmVzcG9uc2UtY29udGVudC1kaXNwb3NpdGlvbj1pbmxpbmU7ZmlsZW5hbWU9UlNILTIwTVBfQ3Jvc3NSZWZlcmVuY2VTaGVldF9SNTExMzdfMDIyNFdFQi5wZGYmcmVzcG9uc2UtY29udGVudC10eXBlPWFwcGxpY2F0aW9uL3BkZiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=FFX19NvGaQSxPQXEHMsYm8fqNA3B1CLKn-ZljDpcsmdsRk8O-TvPsKSBSh2a5nYUquuCYC1KDaSmeG6oPF-IeNRfV8BXFdDcQctbnA5tRHgd9r-echEyzVYxCbCdO6He4ndMCPtdgXUbr1o9LSz0TTIAn8RovgUfFuHwKJg1PAucpm71W1ZYJO906rVg4~apWSAUE285yfEq8uvw3EILGeWo9AdGo5lsHzBcavlSxDWXiYGHEdO8yjwlAACR66B2U8NzH~LLWCW418p9y4IGeikzepj-cZWDvkwRwb5BJNdg-vxUQrUtucXUZsjhXvtHBKJqPHvrhj2Rk4MpojTMGA__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cstrong\u003eCross Reference Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?cache=1710343735\u0026amp;response-content-disposition=inline;filename=RSH-ProductCatlog-CAT-R50366-0124WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDY~Y2FjaGU9MTcxMDM0MzczNSZyZXNwb25zZS1jb250ZW50LWRpc3Bvc2l0aW9uPWlubGluZTtmaWxlbmFtZT1SU0gtUHJvZHVjdENhdGxvZy1DQVQtUjUwMzY2LTAxMjRXRUIucGRmJnJlc3BvbnNlLWNvbnRlbnQtdHlwZT1hcHBsaWNhdGlvbi9wZGYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=PMR6aaUbpSSib0IK0bJwgMV9BDEMUtRRoUN2NLs~OAjDBPV2r-PEFydiJIknG896fQFs4Z2aaMaWWa~rf8PrN~EiOtlnSF4OuGwaMWPsTnbLAf7kjzX6xmZe5nkDFvWEaVI0NrAgijXtOorJ5Ijs-gKdj0MwJLZ8Anq-1dJi5AOlTa~XC~HLwMLnJHPXL9foQhunrZ6iVKLfzOiBqWmFJ-TvUa2Mo0issEMjlrokTOGgKOx3g03Y92EvW6wBhyMvcpVPC10Vv4tN4QufhEuh3w6jae7HZMT7ofoFGJna3F762I9QNXhL21OYK9UHs0wfJayJBEsV0kneJ2WFu5Z~4g__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan\u003eRSH Series Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/Gj_5SuBv8PM?si=rb7Hsr1DZ0OC9HmJ\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":49124238426328,"sku":"96429","price":50.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/96429.png?v=1750735785"},{"product_id":"rectorseal-96430-rsh-20-motor-surge-protector-azure","title":"RectorSeal 96430 RSH-20 Motor Surge Protector, Azure","description":"\u003ch1\u003eRectorSeal 96430 RSH-20 Motor Surge Protector, Azure\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eRSH-20MP-AZ Surge Protective Device (SPD) for Single-Phase 120\/240 VAC Indoor Azure Motors\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Recognized\u003c\/li\u003e\n\u003cli\u003eThermally Fused MOVs\u003c\/li\u003e\n\u003cli\u003e5 Year Limited Product Warranty\u003c\/li\u003e\n\u003cli\u003ePlug-n-Play for Ease of Installation\u003c\/li\u003e\n\u003cli\u003eDiagnostic LED indicates Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eProtects single phase 120\/240V Azure ECM indoor blower motors from transient over-voltage and natural-cause surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended for \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFor single phase 120\/240 VAC ECM Azure indoor motors\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Voltage – 120\/240 VAC\u003c\/li\u003e\n\u003cli\u003eMax discharge current per phase – 20kA (1 hit\u003cbr\u003esurvivability)\u003c\/li\u003e\n\u003cli\u003eNominal discharge current – 5kA (15 hits\u003cbr\u003esurvivability)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Recognized\u003c\/li\u003e\n\u003cli\u003eThermally Fused MOV Technology for safety \u0026amp; performance\u003c\/li\u003e\n\u003cli\u003eLimited 5 year warranty \u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003e3 modes of protection: L-G, \u003c\/span\u003eN-G, L-N\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003ePlug-n-Play for ease of \u003c\/span\u003einstallation\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003eDiagnostic LED indicates \u003c\/span\u003eprotection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_156630584?cache=1709730706\u0026amp;response-content-disposition=inline;filename=RSH-20MP_CrossReferenceSheet_R51137_0224WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfMTU2NjMwNTg0P2NhY2hlPTE3MDk3MzA3MDYmcmVzcG9uc2UtY29udGVudC1kaXNwb3NpdGlvbj1pbmxpbmU7ZmlsZW5hbWU9UlNILTIwTVBfQ3Jvc3NSZWZlcmVuY2VTaGVldF9SNTExMzdfMDIyNFdFQi5wZGYmcmVzcG9uc2UtY29udGVudC10eXBlPWFwcGxpY2F0aW9uL3BkZiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=FFX19NvGaQSxPQXEHMsYm8fqNA3B1CLKn-ZljDpcsmdsRk8O-TvPsKSBSh2a5nYUquuCYC1KDaSmeG6oPF-IeNRfV8BXFdDcQctbnA5tRHgd9r-echEyzVYxCbCdO6He4ndMCPtdgXUbr1o9LSz0TTIAn8RovgUfFuHwKJg1PAucpm71W1ZYJO906rVg4~apWSAUE285yfEq8uvw3EILGeWo9AdGo5lsHzBcavlSxDWXiYGHEdO8yjwlAACR66B2U8NzH~LLWCW418p9y4IGeikzepj-cZWDvkwRwb5BJNdg-vxUQrUtucXUZsjhXvtHBKJqPHvrhj2Rk4MpojTMGA__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cstrong\u003eCross Reference Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?cache=1710343735\u0026amp;response-content-disposition=inline;filename=RSH-ProductCatlog-CAT-R50366-0124WEB.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDY~Y2FjaGU9MTcxMDM0MzczNSZyZXNwb25zZS1jb250ZW50LWRpc3Bvc2l0aW9uPWlubGluZTtmaWxlbmFtZT1SU0gtUHJvZHVjdENhdGxvZy1DQVQtUjUwMzY2LTAxMjRXRUIucGRmJnJlc3BvbnNlLWNvbnRlbnQtdHlwZT1hcHBsaWNhdGlvbi9wZGYiLCJDb25kaXRpb24iOnsiRGF0ZUxlc3NUaGFuIjp7IkFXUzpFcG9jaFRpbWUiOjIxNDc0MTQ0MDB9fX1dfQ__\u0026amp;Signature=PMR6aaUbpSSib0IK0bJwgMV9BDEMUtRRoUN2NLs~OAjDBPV2r-PEFydiJIknG896fQFs4Z2aaMaWWa~rf8PrN~EiOtlnSF4OuGwaMWPsTnbLAf7kjzX6xmZe5nkDFvWEaVI0NrAgijXtOorJ5Ijs-gKdj0MwJLZ8Anq-1dJi5AOlTa~XC~HLwMLnJHPXL9foQhunrZ6iVKLfzOiBqWmFJ-TvUa2Mo0issEMjlrokTOGgKOx3g03Y92EvW6wBhyMvcpVPC10Vv4tN4QufhEuh3w6jae7HZMT7ofoFGJna3F762I9QNXhL21OYK9UHs0wfJayJBEsV0kneJ2WFu5Z~4g__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan mce-data-marked=\"1\"\u003eRSH Series Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Gj_5SuBv8PM?si=rb7Hsr1DZ0OC9HmJ\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":49124261724376,"sku":"96430","price":50.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/96430.png?v=1751411387"},{"product_id":"icm-controls-sentry-3n1-surge-disconnect-line-voltage-monitor","title":"ICM Controls Sentry 3N1 Surge Disconnect Line Voltage Monitor","description":"\u003ch1\u003eICM Controls Sentry 3N1 Surge Disconnect Line Voltage Monitor\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003e\u003cb\u003eSingle Phase\u003cspan class=\"m_1198432128764236234apple-converted-space\"\u003e \u003c\/span\u003e\u003cspan class=\"m_1198432128764236234outlook-search-highlight\"\u003eSurge\u003c\/span\u003e\u003cspan class=\"m_1198432128764236234apple-converted-space\"\u003e \u003c\/span\u003eProtection, Line Voltage Monitoring, and Disconnect\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Sentry 3N1 combines the benefits of a ICM517A single phase surge protective device, and an ICM492 single phase voltage monitor while incorporating a disconnect breaker into one easy to install solution. It provides techs and homeowners a convenient way to break the power, protect against power surges and over\/under voltage issues that can cause damage to circuit boards and motors in residential and commercial single phase 240 VAC HVAC\/R equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll Components Pre-wired for 240 volts\u003c\/li\u003e\n\u003cli\u003eModular Design with field replaceable components\u003c\/li\u003e\n\u003cli\u003eField Programmable Voltage Monitor\u003c\/li\u003e\n\u003cli\u003e5-fault memory for Voltage Monitor\u003c\/li\u003e\n\u003cli\u003eEasy-view backlit, LCD digital display on Voltage Monitor\u003c\/li\u003e\n\u003cli\u003eProtects against over and under voltage, and rapid short cycling\u003c\/li\u003e\n\u003cli\u003eSeparate 40amp Contactor, fully disconnects from the service\u003c\/li\u003e\n\u003cli\u003e40amp internal breaker allows for easy switching of power on and off\u003c\/li\u003e\n\u003cli\u003eSuperior TMOV technology provides safe and reliable surge protection\u003c\/li\u003e\n\u003cli\u003eBuilt to withstand the high impact of a major surge event\u003c\/li\u003e\n\u003cli\u003eProudly Assembled in America\u003c\/li\u003e\n\u003cli\u003eNEMA type 4X Rating\u003c\/li\u003e\n\u003cli\u003eLimited lifetime product. Up to a 3-year $10,000 connected equipment warranty\u003c\/li\u003e\n\u003cli\u003eUL Listed: ICM517A – E347279\u003c\/li\u003e\n\u003cli\u003eUL Rated: ICM492 – E53944\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICM517A Surge Suppressor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum Surge Current: 100,000 amps\u003c\/li\u003e\n\u003cli\u003eDiagnostics green light indicates surge suppression present\u003c\/li\u003e\n\u003cli\u003eProtection modes: L-L, L-G\u003c\/li\u003e\n\u003cli\u003eRobust cast aluminum enclosure for secondary safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eICM492 Voltage Monitor:\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUser Adjustable settings:\u003c\/li\u003e\n\u003cli\u003eVoltage set point: 95-280 VAC\u003c\/li\u003e\n\u003cli\u003eAnti-short cycle time delay: 0-720 seconds\u003c\/li\u003e\n\u003cli\u003eOver\/under voltage setting: 5-25%\u003c\/li\u003e\n\u003cli\u003eResponse time: 0.1 to 10 seconds\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±2%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLine voltage: 240 VAC\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eBreaker: 40 amp at 240 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: Contactor\u003c\/li\u003e\n\u003cli\u003e2-Pole contact ratings: 40A FLA, 240A LRA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eREPLACES:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eRectorSeal:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eRSH-50VRM Kit-DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2025\/02\/11-13-2024-Doc-id-000-29-4823-Rev-A-LIS514_ICMSentry3N1_Sell-Sheet-Approved.pdf\"\u003eSell Sheet \u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2025\/03\/Sentry3N1-LIAF339-1_03112025_Crop_BW_Web.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/9NL739dxR3c?si=SA8gvGR3lN7FAxR_\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":50371973513432,"sku":"Sentry 3N1","price":391.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/Srenry3N1-768x1024.webp?v=1745273554"},{"product_id":"icm-controls-3vms-3-phase-surge-protection-and-3-phase-voltage-monitor","title":"ICM Controls 3VMS 3-Phase Surge Protection and 3-Phase Voltage Monitor","description":"\u003ch1\u003eICM Controls 3VMS 3-Phase Surge Protection and 3-Phase Voltage Monitor\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 3VMS combines the benefits of the ICM450A programmable 3-phase line voltage monitor and a ICM530 type 1 and type 2 three-phase Surge Protective Device into one easy to install solution. The 3VMS protects against both power surges and over\/under voltage issues that can cause damage to circuit boards and motors in residential and commercial three-phase 208\/240 VAC HVAC\/R equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll components pre-wired for 208\/240 volts\u003c\/li\u003e\n\u003cli\u003eModular design with field replaceable components\u003c\/li\u003e\n\u003cli\u003eField programmable voltage monitor with backlit LCD display and a large fault history\u003c\/li\u003e\n\u003cli\u003eProtects against over and under voltage, phase loss, phase reversal, phase unbalance and rapid short cycling\u003c\/li\u003e\n\u003cli\u003eSeparate 40amp contactor, fully disconnects from the service\u003c\/li\u003e\n\u003cli\u003eSuperior TMOV technology provides safe and reliable surge protection, up to 150 kA max surge event\u003c\/li\u003e\n\u003cli\u003eBuilt to withstand the high impact of a major surge event\u003c\/li\u003e\n\u003cli\u003eNEMA type 4X Rating\u003c\/li\u003e\n\u003cli\u003eLimited lifetime product warranty up to a 3-year $10,000 connected equipment warranty.\u003c\/li\u003e\n\u003cli\u003eUL Listed: ICM450A UL file number E53944\u003c\/li\u003e\n\u003cli\u003eUL Listed: ICM530 UL file number E347279\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eICM530 Surge Protection Device:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum Surge Current: 150,000 amps\u003c\/li\u003e\n\u003cli\u003eDiagnostic green LED light indicates surge protection present\u003c\/li\u003e\n\u003cli\u003eProtection modes: L-L, L-N\u003cbr\u003e(L-N protection available only when Neutral is connected)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eICM450A 3-Phase Line Voltage Monitor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser Adjustable settings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage set point: 208\/240 VAC\u003cbr\u003e(do not set above 240VAC)\u003c\/li\u003e\n\u003cli\u003eDelay on Fault: 0- 15 seconds\u003c\/li\u003e\n\u003cli\u003ePercent Unbalance: 2% – 20%\u003cbr\u003e(do not set above 10%)\u003c\/li\u003e\n\u003cli\u003eAnti-short cycle time delay: 15 sec to 10 min\u003c\/li\u003e\n\u003cli\u003eOver\/under voltage setting: 2-25%\u003cbr\u003e(do not set above 5% when voltage set point is 240VAC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLine voltage: 208\/240 VAC\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType: Relay, SPDT\u003c\/li\u003e\n\u003cli\u003e2-Pole contact ratings: 40A, 208\/240 VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2025\/03\/LIS516-1_3VMS_Sell-Sheet.pdf\"\u003eSell Sheet \u003c\/a\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2025\/03\/LIAF340-1_3VMS_Instruction.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":50372002840792,"sku":"3VMS","price":829.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/3VMS-705x651.png?v=1750990324"},{"product_id":"rectorseal-96417-rsh-50-with-30a-fused-disconnect","title":"RectorSeal 96417 RSH-50 with 30A Fused Disconnect","description":"\u003ch1\u003eRectorSeal 96417 RSH-50 with 30A Fused Disconnect\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDisconnect Box with a pre-installed RSH-50 Surge Protector. Our RSH-50 is tabbed into the disconnect, to avoid any potential code violations with multiple wires being lugged in.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFused Disconnect Box\u003c\/li\u003e\n\u003cli\u003eLong-Lasting Gas Discharge Tube Technology\u003c\/li\u003e\n\u003cli\u003eTFMOV Technology\u003c\/li\u003e\n\u003cli\u003eGreen LED Easily Indicates Protection\u003c\/li\u003e\n\u003cli\u003eDesigned to protect all single phase, 120\/240-V air conditioning, heat pumps and ductless mini-split systems (DMSS) from transient over-voltage and natural-cause surges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor residential or commercial use. Protects up to 50,000-amp single surges and up to 10,000-amp repetitive surges.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_93799706?cache=1595253040\u0026amp;response-content-disposition=inline;filename%253DRSH-SurgeProtector-FLY-R50366-0720web.pdf\u0026amp;response-content-type=application\/pdf\u0026amp;Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTM3OTk3MDY~Y2FjaGU9MTU5NTI1MzA0MCZyZXNwb25zZS1jb250ZW50LWRpc3Bvc2l0aW9uPWlubGluZTtmaWxlbmFtZSUyNTNEUlNILVN1cmdlUHJvdGVjdG9yLUZMWS1SNTAzNjYtMDcyMHdlYi5wZGYmcmVzcG9uc2UtY29udGVudC10eXBlPWFwcGxpY2F0aW9uL3BkZiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=AjXaKf6DL19TCv3gRJ08PxVAkoiktkLMcpVfG3hOvnxM6Hs-vpAgE9KA7BdLBY4JKrxSntsBvtVNY3cDb66c5b6QJi87iq6qAqiv4PiRdk7u0IQnSwwTu-4tF5rjodpE4kKqeKX0~xfTqJn~U7~APbUhJhO7K1IRc~VmLBscCYLNcvBrX8mADmn~32-94F5kNemUk4NjWcF~jZYbxu3dD1nvZTyTgXBus~Bq9GidSQ~Vzbu8b7eEKdg8jY6wb4LTILco~usH4-9zcHtrRkGvTKo~lm6Gyy08KiG7GczmYgaN9IV4UwO1xeA4w0jm92gg9CvAVegwStX~iuHSK0js3A__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan\u003e\u003cstrong\u003eRSH Series Brochure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn1-originals.webdamdb.com\/13771_98290057_2?Policy=eyJTdGF0ZW1lbnQiOlt7IlJlc291cmNlIjoiaHR0cCo6Ly9jZG4xLW9yaWdpbmFscy53ZWJkYW1kYi5jb20vMTM3NzFfOTgyOTAwNTdfMiIsIkNvbmRpdGlvbiI6eyJEYXRlTGVzc1RoYW4iOnsiQVdTOkVwb2NoVGltZSI6MjE0NzQxNDQwMH19fV19\u0026amp;Signature=bXjcrZJ8awjMYil0ANIglerfUjbj-zP-YlL~AJ4WWSYfg~-N6ZNWGoEbS5igQBwLoW28P5D5vSf7BEQgNsW8XSLhwYIUX9ALOKHmHj0xG2q-T61x-jbvZIO~0djtLO56a28QJ-Up-Q7yNpttjWTA7KZwOLqnoGt--KALlOAryMuuIAlNoZ0nz07FtWAJ6vyX4L3GZFwXdCZd82Iio57l26GhmWyd~szd7gJVec-CpeDP~Q6vznINhpFMqv0z~7ftCdaQUD5VYeSy~N1v4eMVxJCGfZE5C1UQN8hHHdpEVamhorn1Wg5Ce5KGSvDRyHfYzBtzBm3TeBeGiAWMS4ahgA__\u0026amp;Key-Pair-Id=APKAI2ASI2IOLRFF2RHA\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan\u003eHomeowner Flyer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/PnsGwpoouvY\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/R4pzP5FAldU\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":50460514058456,"sku":"96417","price":158.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/Screenshot2025-05-22160912.png?v=1751428357"},{"product_id":"icm-controls-icm517a-single-phase-type-2-surge-protective-device","title":"ICM Controls ICM517A Single-Phase, Type 2 Surge Protective Device","description":"\u003ch1\u003eICM Controls ICM517A Single-Phase, Type 2 Surge Protective Device\u003c\/h1\u003e\n\u003cp\u003eThe ICM517A is a NEMA Type 4X enclosed Type 2 Surge Protective Device (SPD) designed to protect valuable single-phase equipment by dissipating momentary voltage spikes and transient power surges. Applications include the protection of motors, electronics, air conditioning systems, appliances, refrigeration, and more.\u003c\/p\u003e\n\u003cp\u003eThe tried and true, preexisting industry favorite ICM517 SPD recently received an update, which prompted the designation of an “A” to the end of the preexisting part number. With 100,000’s of ICM517’s installed in the field, ICM stayed true to the rugged \u0026amp; reliable design of the existing “go to” SPD, the new ICM517A Type 2 Surge Protective Device is now constructed even more robust.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"li1\"\u003eBuilt to withstand the high impact of a major surge event\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eConstructed in a robust Cast Aluminum enclosure for maximum durability\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eFeaturing a redesigned rivet sealed molded case with an internal gasket\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eNema Type 4X rated for indoor\/outdoor installation\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eFeaturing a thinner, more compact profile then previous versions\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eUpdated to the latest addition of UL standards\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eWithstands effects of prolonged UV exposure better then ABS plastics\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eUL Rated Powder Coating for superior corrosion resistance\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eEasy Installation\u003c\/li\u003e\n\u003cli class=\"li1\"\u003eProudly Made in America\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eService Voltage:\u003c\/strong\u003e 120\/240 volt, single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Surge Current:\u003c\/strong\u003e 100,000 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Energy Dissipation:\u003c\/strong\u003e 1,020 Joules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Point:\u003c\/strong\u003e\u003cbr\u003e– Electrical Panel\u003cbr\u003e– E\u003cspan\u003electrical disconnect\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics: \u003c\/strong\u003eGreen light indicates surge suppression is present\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Protection Modes:\u003c\/strong\u003e L-L, L-N, L-G, N-G\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Connection:\u003c\/strong\u003e 3\/4″\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 5″L x 3.06″W x 1.75″H\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.18 lbs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eREPLACES:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCrosses to comparable SPD’s from the following companies. Particular features can vary:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eABB, Square D, Eaton, Ditek, Intermatic, Mars, RectorSeal, Supco\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2022\/12\/ICM517A-LIS449.pdf\"\u003eSell Sheet \u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2022\/12\/ICM517A-LIAF212-8.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2022\/12\/LIM362-ICM517A-Homeowner-Trifold-1.pdf\"\u003eHomeowner Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2022\/12\/LIM358-ICM517A-Internal-Description.pdf\"\u003eInternal Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2022\/12\/LIAF336-ICM517A-Limited-Lifetime-Warranty.pdf\"\u003eWarranty Information\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":50538790289624,"sku":"ICM517A","price":88.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/ICM517A-Alt-web4.jpg?v=1751380854"},{"product_id":"icm-controls-icm517a-lite-split-phase-type-2-surge-protective-device","title":"ICM Controls ICM517A-LITE Split-Phase, Type 2 Surge Protective Device","description":"\u003ch1\u003eICM Controls ICM517A-LITE Split-Phase, Type 2 Surge Protective Device\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe ICM517A-Lite is a compact Type 2 Surge Protective Device (SPD) designed to protect valuable single-phase equipment by dissipating momentary voltage spikes and transient power surges. Providing commercial property owners with peace of mind, contractors with a reliable selling proposition and wholesalers with a high demand product. Applications include the protection of motors, electronics, air conditioning systems, appliances, refrigeration, HVAC equipment and more.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuperior TMOV technology provides safe and reliable surge protection\u003c\/li\u003e\n\u003cli\u003eBuilt to withstand the high impact of a major surge event\u003c\/li\u003e\n\u003cli\u003eUltrasonically welded enclosure for indoor\/outdoor installation\u003c\/li\u003e\n\u003cli\u003eFeaturing a thinner more compact profile\u003c\/li\u003e\n\u003cli\u003eMaximum surge capacity of 60,000 amps\u003c\/li\u003e\n\u003cli\u003eEasy-to-read status light, tells you when the control is protecting\u003c\/li\u003e\n\u003cli\u003eEasy installation\u003c\/li\u003e\n\u003cli\u003eDesigned and assembled in U.S.A.\u003c\/li\u003e\n\u003cli\u003eUL Listed: E347279\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eService Voltage:\u003c\/strong\u003e 120\/240 volt, single phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Surge Current:\u003c\/strong\u003e 60,000 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Energy Dissipation:\u003c\/strong\u003e 612 Joules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Point:\u003c\/strong\u003e\u003cbr\u003e– Electrical Panel\u003cbr\u003e– E\u003cspan\u003electrical disconnect\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics: \u003c\/strong\u003eGreen light indicates surge suppression is present\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure: \u003c\/strong\u003e\u003cspan\u003eNEMA Type 4X waterproof enclosure\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Protection Modes:\u003c\/strong\u003e L-L, L-G\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Connection:\u003c\/strong\u003e 1\/2″ trade size\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 3.75″L x 2.25″W x 1.02″H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eREPLACES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRectorSeal: RSH-50\u003c\/li\u003e\n\u003cli\u003eSupco: SCM60\u003c\/li\u003e\n\u003cli\u003eIntermatic: L5F21S1DG1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2025\/08\/LIS520-1_ICM517A-Lite-Sell-Sheet_8.5x11-Approved.pdf\"\u003eSell Sheet \u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2025\/08\/LIAF344-ICM517A-Lite.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003ca href=\"https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2022\/12\/LIM362-ICM517A-Homeowner-Trifold-1.pdf\"\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/YhjsNDdIgqE?si=PSVxaOO-FG4AlDwA\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":50730373415128,"sku":"ICM517A-LITE","price":65.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/ICM517A-Lite-Cover-Render-08012025.webp?v=1755034631"},{"product_id":"ditek-dtk-120-240bk1-circuit-breaker-surge-protective-device","title":"Ditek DTK-120-240BK1 Circuit Breaker Surge Protective Device","description":"\u003ch1\u003eDitek DTK-120-240BK1 Circuit Breaker Surge Protective Device\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eDitek DTK-120\/240BK1 is a UL classified circuit breaker-style surge protective device designed and manufactured to fit a variety of residential load centers with 1” breaker spacing. This SPD is specifically designed for 120\/240V split phase systems, and incorporates the latest thermally-protected MOV technology. Standard features include an LED diagnostic indicator and audible alarm with silence switch. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstalls directly on to load center bus bars\u003c\/li\u003e\n\u003cli\u003eThermally-protected MOV technology\u003c\/li\u003e\n\u003cli\u003eAudible alarm w\/ silence feature\u003c\/li\u003e\n\u003cli\u003eDiagnostic LED provides visual indication of system power and SPD function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Center Capabilities \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSquare D Homeline Series: Circuit breaker type “HOM”\u003c\/li\u003e\n\u003cli\u003eEaton BR Series: Circuit breaker type “BR”\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSiemens EQ, PL, ES, PN, SN Series: Circuit breaker type “Q” or “QP”\u003c\/li\u003e\n\u003cli\u003eGE PowerMark Gold Series: Circuit breaker type “THQL”\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResidential Electrical Panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.diteksurgeprotection.com\/wp-content\/uploads\/DTK-120-240BK1-DS-R1.pdf\"\u003e\u003cstrong\u003eData Sheet \u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.diteksurgeprotection.com\/wp-content\/uploads\/DTK-120_240BK1-191665-R2.pdf\"\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":50859317330136,"sku":"DTK-120-240BK1","price":108.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/DTK-120-240BK1.png?v=1758126156"},{"product_id":"ditek-dtk-kg2-kool-guard-series-intelligent-voltage-monitoring","title":"Ditek DTK-KG2 Kool Guard Series Intelligent Voltage Monitoring","description":"\u003ch1\u003eDitek DTK-KG2 Kool Guard Series Intelligent Voltage Monitoring\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Voltage Monitoring Protects Vulnerable HVAC Equipment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDITEK’s DTK-KG2 is part of the Kool Guard family of voltage monitoring products. It is specifically designed to protect HVAC equipment from harmful undervoltage and overvoltage events that can damage sensitive electronics and mechanical components within the system. The DTK-KG2 also incorporates DITEK’s state-of-the-art surge protection design to shield the equipment from damaging transient voltage surges and spikes. The standard UL Type 4X polycarbonate enclosure allows the unit to be easily installed in harsh outdoor environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtection for undervoltage \u0026amp; overvoltage events on 120\/240VAC or 120\/208VAC split phase circuits up to 40A\u003c\/li\u003e\n\u003cli\u003eAuto-calibration feature eliminates the need to manually calibrate the unit to the specific input voltage \u003c\/li\u003e\n\u003cli\u003eSafely disconnects power to the system for 3 minutes allowing input voltage to return to normal range\u003c\/li\u003e\n\u003cli\u003eIdeal protection for inverter-driven compressor systems and mini-splits\u003c\/li\u003e\n\u003cli\u003eDiagnostic red and green LEDs indicate exactly what voltage condition is present\u003c\/li\u003e\n\u003cli\u003eSurge protection components included to divert harmful transient voltages away from the equipment\u003c\/li\u003e\n\u003cli\u003eAccepts 1\/2\" or 3\/4\" NPT flexible conduit\u003c\/li\u003e\n\u003cli\u003eUL Listed\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply: Split Single Phase\u003c\/li\u003e\n\u003cli\u003eVolts: 120 - 240\u003c\/li\u003e\n\u003cli\u003eDucted or Ductless: Ducted or Ductless\u003c\/li\u003e\n\u003cli\u003eSurge Capacity (kA): 50kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv class=\"tab-content__wrapper\"\u003e\n\u003clabel class=\"entity-label\"\u003ePrimary Depth (inches) \u003c\/label\u003e6.29\u003clabel class=\"entity-label\"\u003e\u003c\/label\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv class=\"tab-content__wrapper\"\u003e\n\u003clabel class=\"entity-label\"\u003ePrimary Width (inches) \u003c\/label\u003e2.36\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv class=\"tab-content__wrapper\"\u003e\n\u003clabel class=\"entity-label\"\u003e\u003c\/label\u003e\u003clabel class=\"entity-label\"\u003ePrimary Height (inches) \u003c\/label\u003e6.29\u003clabel class=\"entity-label\"\u003e\u003c\/label\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv class=\"tab-content__wrapper\"\u003e\n\u003clabel class=\"entity-label\"\u003ePrimary Weight (lbs) \u003c\/label\u003e3\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/s3.us-west-2.amazonaws.com\/catsy.898\/DTK-KG2+TDS.pdf\"\u003eTechnical Data Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":50859340529880,"sku":"DTK-KG2","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/DTK-KG2.png?v=1758127222"},{"product_id":"icm-controls-3vms-60-480-3-phase-surge-protection-and-3-phase-voltage-monitor-60a-480vac","title":"ICM Controls 3VMS-60-480 3-Phase Surge Protection and 3-Phase Voltage Monitor 60A, 480VAC","description":"\u003ch1\u003eICM Controls 3VMS-60-480 3-Phase Surge Protection and 3-Phase Voltage Monitor 60A, 480VAC\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe 3VMS combines the benefits of the ICM450A PLUS+ programmable 3-phase line voltage monitor and a ICM531 type 1 and type 2 three-phase Surge Protective Device (SPD) into one easy-to-install solution. The 3VMS protects against both power surges and over\/under voltage issues that can cause damage to circuit boards and motors in residential and commercial three-phase 480VAC HVAC\/R equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*All individual components are replaceable\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll Components pre-wired for 480VAC\u003c\/li\u003e\n\u003cli\u003eModular design with field replaceable components\u003c\/li\u003e\n\u003cli\u003eField programmable voltage monitor with backlit LCD display and large fault history\u003c\/li\u003e\n\u003cli\u003eProtects against over and under voltage, phase loss, phase reversal, phase unbalance and rapid short cycling\u003c\/li\u003e\n\u003cli\u003eReal time clock for date and time stamp of fault events\u003c\/li\u003e\n\u003cli\u003eSeparate 3-pole, 60amp contactor, fully disconnects from the service\u003c\/li\u003e\n\u003cli\u003eSuperior TFMOV technology provides safe and reliable surge protection, up to 150kA max surge event\u003c\/li\u003e\n\u003cli\u003eBuilt to withstand the high impact of a major surge event\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Rating\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUL Listed: E518971\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Voltage: 480VAC\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 400 – 525VAC\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eSCCR: 5kA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContactor: 60A FLA, 480VAC\u003c\/li\u003e\n\u003cli\u003eSurge Protection Device: Maximum surge current: 150,000 amps\u003c\/li\u003e\n\u003cli\u003eDiagnostic green LED light indicates surge protection present\u003c\/li\u003e\n\u003cli\u003eProtection modes: L-L, L-N\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLine Voltage Monitor (3VMS Default Settings):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage set point: 480VAC\u003c\/li\u003e\n\u003cli\u003ePhase Unbalance: 7%\u003c\/li\u003e\n\u003cli\u003eOver\/Under Voltage: 5%\u003c\/li\u003e\n\u003cli\u003eDelay on Break (ASC) : 15 seconds\u003c\/li\u003e\n\u003cli\u003eDelay on Fault: 3 seconds\u003c\/li\u003e\n\u003cli\u003eReset Mode: 0 (auto)\u003c\/li\u003e\n\u003cli\u003eControl Mode: OFF\u003c\/li\u003e\n\u003cli\u003eDate and Time: ON\u003c\/li\u003e\n\u003cli\u003eLanguage: English\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\/Dimensions: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeight: 13 lbs.\u003c\/li\u003e\n\u003cli\u003eLength: 15.7”\u003c\/li\u003e\n\u003cli\u003eWidth: 11.7”\u003c\/li\u003e\n\u003cli\u003eDepth: 6.3”\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ca href=\"chrome-extension:\/\/efaidnbmnnnibpcajpcglclefindmkaj\/https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2026\/02\/LIS523_3VMS-60A-480V.pdf\"\u003eSell Sheet \u003c\/a\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ca href=\"chrome-extension:\/\/efaidnbmnnnibpcajpcglclefindmkaj\/https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2026\/02\/LIAF347_3VMS-60-480.pdf\"\u003eInstallation Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":51415861166296,"sku":"3VMS-60-480","price":1096.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/3VMS-60-480-scaled.png?v=1771897879"},{"product_id":"icm-controls-3vms-60-208-3-phase-surge-protection-and-3-phase-voltage-monitor-60a-480vac-copy","title":"ICM Controls 3VMS-60-208 3-Phase Surge Protection and 3-Phase Voltage Monitor 60A, 208VAC","description":"\u003ch1\u003eICM Controls 3VMS-60-208 3-Phase Surge Protection and 3-Phase Voltage Monitor 60A, 208VAC\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe 3VMS combines the benefits of the ICM450A PLUS+ programmable 3-phase line voltage monitor and a ICM531 type 1 and type 2 three-phase Surge Protective Device (SPD) into one easy-to-install solution. The 3VMS protects against both power surges and over\/under voltage issues that can cause damage to circuit boards and motors in residential and commercial three-phase 208VAC HVAC\/R equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e*All individual components are replaceable\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll Components pre-wired for 208VAC\u003c\/li\u003e\n\u003cli\u003eModular design with field replaceable components\u003c\/li\u003e\n\u003cli\u003eField programmable voltage monitor with backlit LCD display and large fault history\u003c\/li\u003e\n\u003cli\u003eProtects against over and under voltage, phase loss, phase reversal, phase unbalance and rapid short cycling\u003c\/li\u003e\n\u003cli\u003eReal time clock for date and time stamp of fault events\u003c\/li\u003e\n\u003cli\u003eSeparate 3-pole, 60amp contactor, fully disconnects from the service\u003c\/li\u003e\n\u003cli\u003eSuperior TFMOV technology provides safe and reliable surge protection, up to 150kA max surge event\u003c\/li\u003e\n\u003cli\u003eBuilt to withstand the high impact of a major surge event\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Rating\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUL Listed: E518971\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal Voltage: 208 VAC\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 190 – 252VAC\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eSCCR: 5kA\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContactor: 60A FLA, 208\/240VAC\u003c\/li\u003e\n\u003cli\u003eSurge Protection Device: Maximum surge current: 150,000 amps\u003c\/li\u003e\n\u003cli\u003eDiagnostic green LED light indicates surge protection present\u003c\/li\u003e\n\u003cli\u003eProtection modes: L-L, L-N\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLine Voltage Monitor (3VMS Default Settings):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage set point: 240VAC\u003c\/li\u003e\n\u003cli\u003ePhase Unbalance: 7%\u003c\/li\u003e\n\u003cli\u003eOver\/Under Voltage: 5%\u003c\/li\u003e\n\u003cli\u003eDelay on Break (ASC) : 15 seconds\u003c\/li\u003e\n\u003cli\u003eDelay on Fault: 3 seconds\u003c\/li\u003e\n\u003cli\u003eReset Mode: 0 (auto)\u003c\/li\u003e\n\u003cli\u003eControl Mode: OFF\u003c\/li\u003e\n\u003cli\u003eDate and Time: ON\u003c\/li\u003e\n\u003cli\u003eLanguage: English\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\/Dimensions: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeight: 13 lbs.\u003c\/li\u003e\n\u003cli\u003eLength: 15.7”\u003c\/li\u003e\n\u003cli\u003eWidth: 11.7”\u003c\/li\u003e\n\u003cli\u003eDepth: 6.3”\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003ca href=\"chrome-extension:\/\/efaidnbmnnnibpcajpcglclefindmkaj\/https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2026\/02\/LIS524_3VMS-60-208.pdf\"\u003e\u003cstrong\u003eSell Sheet \u003c\/strong\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003ca href=\"chrome-extension:\/\/efaidnbmnnnibpcajpcglclefindmkaj\/https:\/\/www.icmcontrols.com\/wp-content\/uploads\/2026\/02\/LIAF348_3VMS-60-208.pdf\"\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Edmondson Supply","offers":[{"title":"Default Title","offer_id":51428441325784,"sku":"3VMS-60-208","price":1023.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0011\/6709\/7956\/files\/3VMS-60-208-scaled_724d8277-2264-4e98-b196-8f734ace7f1c.webp?v=1772227827"}],"url":"https:\/\/edmondsonsupply.com\/collections\/surge-protection.oembed","provider":"Edmondson Supply","version":"1.0","type":"link"}